Troubleshooting; Deleting The Pairing Of The Receiver With The Thermostat, Tydom Or Window Sensor; Removing Pairings From The Receiver; Technical Characteristics - DELTA DORE Tybox 5701FP Quick Start Manual

Hide thumbs Also See for Tybox 5701FP:
Table of Contents

Advertisement

8. Troubleshooting

8.1 Deleting the pairing of the receiver with the thermostat,
Tydom or window sensor
In the event of a fault, you may have to unpair a product and/or repair a new one.
In the first instance, you should delete the receiver from the transmitter (Thermostat, Tydom, etc) as deletion
performed on the receiver will not be synchronised with all transmitters.
Unpairing the receiver from the thermostat
>3s
mode
❶ On the thermostat, press and
hold both the mode and + buttons
for 3 seconds..
The screen will display rF01.
Release the button.

8.2 Removing pairings from the receiver

A
3s
The deletion of wireless pairings with the receiver is carried out by holding down the button.
The LED will cycle through the various states.
: The LED flashes red. The receiver is in pending pairing mode.
: The red LED is on and steady. The receiver is in LED switch off mode.
: The red LED flashes rapidly. The receiver is waiting to delete the pairing with a door/window magnetic contact
(check on the device you want to be unpaired).
: The red LED turns off. All pairings with the receiver are now removed.
: If you hold down the button for 30 seconds, the LED flashes quickly 3 times.
The receiver is fully reset (back to factory settings).

9. Technical characteristics

TYBOX 5101 thermostat
• Power supply using 2 batteries:
2x1.5V Alkaline - Type LR03-AAA
• Class III insulation
• X3D transmission frequency: 868.7 MHz to 869.2 MHz
• Maximum wireless power < 10 mW
• Category II receiver
• Wireless range of 300 metres outside, varies depending on
the paired equipment (the range can vary depending on the
setup conditions and the electromagnetic environment).
• Wall-mounted or on base
• Dimensions: 80 x 84 x 21 mm
• Protection Class: IP 20
• Installation in an environment with normal pollution levels
• Storage temperature: -10°C /+70°C
• Operating temperature from -10°C/+40°C
>3s
❷ Press the button - for 3 seconds
until the screen displays rF00.
Release the button.
> 30s
B
C
6s
10s
RESET OK
To exit the mode, press the Mode
and + buttons simultaneously.
D
20s
RF 6700 receiver
• Power supply 230 V ~, 50 Hz
- Consumption: 0.4 W
• Class II insulation
• Pilot wire output (Comfort/Shutdown)
100 mA max., 230V - Type 1.Y
• Load-shedding input (
• Cable diameter 7mm +/- 0.4mm
• Vertical positioning of the product
• X3D transmission frequency: 868.7 MHz to 869.2 MHz
• Maximum wireless power < 10 mW
• Category II receiver
• Wireless range of 300 metres outside, varies depending on
the paired equipment (the range can vary depending on the
setup conditions and the electromagnetic environment).
• Dimensions: 54 x 140 x 25 mm
• Protection Class: IP 44
• Storage temperature: -10°C /+70°C
• Operating temperature from -10°C/+40°C
• Ball test temperature: 75°C (Housing),
• Rated impulse voltage: 2,500V
E
30s
115V or
230V)
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tybox 5702fpTybox rf6700fp

Table of Contents