8. Troubleshooting

8.1 Deleting the pairing of the receiver with the thermostat

In the event of a fault, you may have to unpair a product and/or repair a new one.
Wireless resetting of the transmitter
1
mode
mode
>3s
❶On the Tybox, briefly press a
button to wake up the display,
then press and hold both the
mode and + buttons for 3 seconds.

8.2 Removing pairings from the receiver

A
3s
The deletion of wireless pairings with the receiver is carried out by holding down the button. The LED will cycle
through the various states.
: The LED flashes red. The receiver is in pending pairing mode.
: The red LED is on and steady. The receiver is in "LED switch off" mode.
: The red LED flashes rapidly. The receiver is waiting for pairing with an opening detector to be deleted (confirm
by briefly pressing the opening detector button).
: The red LED turns off. All pairings with the receiver are now removed.
: If you hold down the button for 30 seconds, the LED flashes quickly 3 times. The receiver is fully reset (back to
factory settings).

9. Technical characteristics

TYBOX 5101 thermostat
• Power supply using 2 batteries:
2x1.5V Alkaline - Type LR03-AAA
• Class III insulation
• X3D transmission frequency: 868.7 MHz to 869.2 MHz
• Maximum wireless power < 10 mW
• Category II receiver
• Wireless range of 300 metres outside, varies depending on
the paired equipment (the range can vary depending on the
setup conditions and the electromagnetic environment).
• Wall-mounted or on base
• Dimensions: 80 x 84 x 21 mm
• Protection Class: IP 20
• Installation in an environment with normal pollution levels
• Storage temperature: -10°C /+70°C
• Operating temperature from -10°C/+40°C
2
>3s
❷ The screen displays rF--
depending on the number of
associated receivers
(e.g.: rF01 for a single receiver, rF02
for 2 receivers etc...).
Press - for 3 seconds to confirm
the reset.
The screen displays rF00.
> 30s
B
C
6s
10s
3
mode
❸ Briefly press the mode and +
buttons at the same time.
The screen displays dF 0
(transmitter not yet associated).
If the receiver is supplied with power
and is within the wireless range of the
transmitter at the time of the reset, the
transmitter will also be deleted on the
receiver.
D
20s
RF 6700 FP receiver
• 230 V~ +/-10%, 50 Hz power supply
• Consumption: 0.4 W
• Class II insulation
• Pilot wire output (Comfort/Shutdown)
100 mA max., 230V - Type 1.Y
• Load-shedding input ( 115V or 230V)
• Cable diameter 7mm +/- 0.4mm
• X3D transmission frequency: 868.7 MHz to 869.2 MHz
• Maximum wireless power < 10 mW
• Category II receiver
• Wireless range of 300 metres outside, varies depending on
the paired equipment (the range can vary depending on the
setup conditions and the electromagnetic environment).
• Dimensions: 54 x 102 x 20 mm
• Protection rating: IP44
- Vertical positioning of the product
• Storage temperature: -10°C /+70°C
• Operating temperature from -10°C/+40°C
• Ball test temperature: 75°C (Housing),
• Rated impulse voltage: 2,500V
E
30s
7

Advertisement