3. Open window detection

If you have associated a motion detector to your installation.
When a window is opened, depending on the heating configuration, the screen indicates:
Heating: Frost protection setpoint (8°C by default) alternating with OPEn.
Air conditioning: «--» alternating with OPEn.

4. Operation with the Tydom application

Your RF6050+ receiver can be associated using the TYDOM application.
Features
Programming
Setting the temperatures
Pre-heat function
Absence mode / Heat mode / Air
conditioning mode
Deactivating the system
In "absence" mode, depending on the heating configuration, the screen of the Tybox indicates :
Heating: Frost protection setpoint (8°C by default) alternating with Ab.
Air conditioning: «--» alternating with Ab.
In "system shutdown mode", the Tybox screen indicates OFF.

5. Troubleshooting

5.1 What the receiver LEDs mean

Signal type
The green light is constantly
on
The red light is constantly
on
The red LED is slowly
flashing
The red LED is flashing
quickly
The green LED is flashing
The 2 LEDs are flashing
simultaneously
(*) Function in backup mode:
- When switching to backup mode, if the receiver control was off, it stays off otherwise it switches to emergency
Frost protection.
- In this Frost Protection Backup (or Stop) mode, pressing the button authorises a manual override.
3 control types are available and are shown by the LEDs flashing:
- 1 flash: Off,
- 2 flashes: Emergency frost protection (heating 15% of the time),
- 3 flashes: Emergency Comfort (heating 75% of the time), 24 hour timer.
You can switch from one to the other by briefly pressing the button.
Via the Tydom app
(temperatures programmed in the app: special events, overrides,
Your equipment automatically determines the start-up time in order
to reach the temperature at the programmed time.
Power supply is on.
The receiver is requesting heat.
The receiver is pending association.
Please refer to the "Associating the receiver(s) to the transmitter" chapter.
The deletion of the association between the receiver and a door/window sensor is
pending.
The receiver isn't associated.
Please refer to the "Associating the receiver(s) to the transmitter" chapter.
No signal has been received by the thermostat for 1 hour.
The receiver is operating in backup mode (*).
Turn the thermostat on by pressing a button.
If the problem persists, make sure that the transmitter is not too far away and that
you have followed the mounting/placement instructions properly.
Yes
Yes
scenario)
Yes
Yes
Yes
Diagnosis/Solutions
11