Detection Area Adjustment - Optex ELITE PRO Instruction Manual

Sensors for full-energy and low-energy automatic swing doors
Hide thumbs Also See for ELITE PRO:
Table of Contents

Advertisement

Detection area adjustment

The first row from the door (row in diagonal line) is called the threshold area and the 2nd and 3rd rows the swing area; the depth angle for each
can be set separately.
With the angle adjustment screws for the threshold and swing areas on the OA-607 T front, each area's depth angle (angle seen from side) can
be independently adjusted between -5 and +5° (respectively SHALLOW and DEEP).
NOTE
NOTE
Recommended detection angle setting: +5°
CAUTION
CAUTION
Adjust the areas in accordance with ANSI 156.10.
Side view
Threshold area
(1st row)
When both threshold
area and swing area are
+5°
-5°
A
: Threshold area (1st row)
: Swing area (2nd/3rd row)
Value dimensions for each door angle
Door angle Door fully closed
A
6'7" (2000)
7'6" (2300)
B
7" (186)
8" (214)
C
1'2" (360)
1'4" (414)
D
6" (152)
7" (175)
E
2'9" (840)
3'2" (966)
F
5'5" (1650)
6'2" (1898)
G
10" (252)
H
1'11" (593)
2'1" (645)
I
3" (89)
6" (141)
J
3' (911)
3'4" (1010)
K
1'4" (407)
1'8" (506)
L
4'2" (1275)
4'8" (1428)
M
2'6" (770)
3' (924)
N
5'6" (1684)
6'3" (1900)
O
3'10" (1180)
4'7" (1395)
Swing area
(2nd,3rd row)
When both threshold
area and swing area are
Sensor pattern
G
H
I
J
K
L
N
30° Open
45° Open
When both threshold
area and swing area are
-5°
+5°
B
D
C
E
F
M
O
60° Open
[feet (mm)]
Door fully opened