Procedures
Color
Error or warning
Red
generated
Orange
„ List of symptoms/causes/countermeasures
Symptom
Auto configuration will
OC-907C T indicators are not
not start
solid
OC-907C T indicators blinking
Orange twice (communication
error) and no indicators solid on
OA-607 T
OC-907C T indicators blinking
Orange twice
OC-907C T/OA-607 T indicators
blinking Blue
Auto configuration
After executing auto configura-
failure
tion, OC-907C T indicator blinks
Orange twice (wiring error)
After executing auto configura-
tion, OC-907C T indicator blinks
Orange (0.5 s intervals) (setting
error)
Intermittent recycle (ghosting) or intermittent stalling
No activation and/or no
OA-607 T sensor detects (solid or
reactivation on closing
blinking Red indicator) (flashing:
cycle
1st row detection, solid: 2nd/3rd
detection) but door does not open
OA-607 T no detection (indicator
solid Green) (stand-by)
OA-607 T indicator is blinking
Orange (configuration error within
setting error)
OA-607 T indicators are blinking
Red and Yellow alternately (in-
complete)
Indicator diagram Status
Blinking twice (0.1 s
interval) (0.7 s unlit)
0.7 s
2 times
Blinking twice (0.1 s
interval) (0.7 s unlit)
0.7 s
2 times
Possible cause
Improper power supply
Power harness connection is unsuitable
Loop harness connection is unsuitable
Pass through harness connection is
unsuitable
Loop harness or pass through harness is
disconnected
More than two OA-607 T have been con-
nected per door
OC-907C T dipswitch setting is incorrect
Activation output (Yellow wire) is not con-
nected correctly
Stall output (Green wire) is not connected
correctly
Automatic recognition (door angle infor-
mation, what configuration and position
sensors are installed in) fails because door
does not operate smoothly
After initial setup door ghosts several times
on first activation
OA-607 T sensor head not mounted flush
on door
Improper threshold or swing area angle
adjustment
Motor voltage input, BodyGuard input, or
close switch input is unsuitable
Stalling caused by traffic just outside of
swing path or objects near guide rails
OA-607 T dipswitch door width setting or
setting app area setting is unsuitable
Objects that move or emit light in the
detection area
The detection area overlaps with that
of another sensor
Water droplets on the detection window
Sensitivity is too high
Raining or snowing
Improper connection of OC-907C T (Yellow
wires) to door controller or ON/OFF/hold
switch
On Knowing act applications poor or
improper connection of knowing act input
(Purple wire) from OC-907C T to the activa-
tion device
Auto configuration failure (configuration
recognition failure) or incorrect setting
Sensitivity is too low
OA-607 T detection window is dirty
Auto configuration is incomplete
Power went off immediately after auto area
learn completion (before auto-saving the
settings)
Door failed to open due to obstacle during
auto area learn
Meaning
Wiring error
One of the wiring errors below with OC-907C T.
Activation output (Yellow wire), stall output (Green wire), test input (Pink
wire), BodyGuard or motor voltage input (Red wire), close switch input
(White wire).
Displayed if the necessary wiring for auto configuration has been
judged incomplete, or if the wiring is temporarily disconnected during
operation.
Communication error
Possible countermeasures
Correct power problem.
Connect the power harness correctly.
Connect the loop harness correctly.
Connect the pass through harness cor-
rectly.
Replace as necessary.
Refer to Wiring and connect OA-607 T
suitably.
Check OC-907C T dipswitch setting.
Refer to Wiring and connect activation
output (Yellow wire) suitably.
Refer to Wiring and connect stall output
(Green wire) suitably.
Set installation positions individually with
the setting app.
Happens in 15% of installations; stopping
after first activation means system is OK.
Head may be resting on top of door loop
cover; reposition head flush on panel.
Set threshold and swing area angles at +5
degrees (Deep).
Refer to Wiring and connect motor voltage
input, BodyGuard input, and close switch
input suitably.
Adjust the detection area via area depth in
the setting app.
Verify proper settings.
Remove the objects.
Change the OA-607 T frequency setting
with the setting app.
Install in a location protected from water
droplets.
Set the sensitivity lower with the setting
app.
Enable immunity or snow mode from the
setting app.
Verify proper connection and output of
activation output (Yellow wires).
Verify proper connection.
Check the suitable settings with the setting
app.
Set the sensitivity higher with the setting
app.
Wipe the detection window with a damp
cloth.
Execute auto configuration (hold down
function switch for 2 s or more).
Execute auto area learn (press function
switch briefly).
Remove the obstacle and then execute
auto area learn (press function switch
briefly).