Wiring
Wire the OC-907C T.
CAUTION
CAUTION
Do not turn the power on while wiring. Otherwise, electric shock or device damage may result.
OC-907C T
Power harness × 1 and door controller interface × 2 (for double door left and right sides) are included.
• Power harness
36"
(920 mm)
Name
1.
Power (*1)
2.
Power (*1)
*1: No polarity.
• I/O harness
I/O harness × 2
(for double door left and right sides)
Name
1.
Activation output
2.
Activation output
3.
None
4.
None
5.
Stall output
6.
Stall output
7.
Test input
8.
Test input
9.
BodyGuard input or
Motor voltage input
10. BodyGuard input or
Motor voltage input
11. None
12. None
13. Knowing act input
14. Knowing act input
15. Close switch input
16. Close switch input
10
Color
Specifications
Orange
12 to 30 VDC
Brown
4'3''
(1300 mm)
Color
I/O
Yellow
Output
Yellow
Output
-
-
-
-
Green
Output
Green
Output
Pink
Input
Pink
Input
Red
Input
Red
Input
-
-
-
-
Purple
Input
Purple
Input
White
Input
White
Input
Specifications
Form A relay 50 V, 0.3 A (resistance load)
At power OFF: Open
At stand-by: Open, at detection: Close
-
Form A or B relay 50 V, 0.3 A (resistance load)
Set form A or B with the setting app.
When setting N.O.
At power OFF: Close
At stand-by: Open
At detection: Close
When setting N.C.
At power OFF: Close
At stand-by: Close
At detection: Open
Optocoupler voltage 5 to 30 VDC, current 6 mA max. (30 VDC) (no polarity)
Optocoupler voltage 5 to 160 VDC, 5 to 120 VAC, 60 Hz (no polarity)
-
Dry contact input
Connect push plate, etc.
Dry contact input
Connect a device recognizing door fully closed status (a magnet switch, etc.).