Wiring door operators from various manufacturers
z Wiring (monitored door)
• Wiring example for single swing door
OC-907C T
Power 12 to 30 VDC
(Polarity free)
Pink
Green
Yellow
White
Red
Purple
OA-607 T
OA-607 T
*1 Do not wire for not monitored door.
*2 How to connect Motor/BG input. (Red wire)
Red
Polarity free for all wiring
Door controller
Test output
Stall input
Activation input
Close switch input
*2
Motor
Knowing act
signal
Door controller
Motor
Time delay module
*1
Relay 1
output
Knowing
act
input
Relay 2
delayed
output
OR
Electric
lock
Knowing act
device
(e.g. Push plate)
Push plate
PUSH
TO OPEN
11