Detection area adjustment

The 1st row from the door (row in diagonal line) is called the threshold area and the 2nd and 3rd rows the swing area; the depth angle for each
can be set separately.
With the angle adjustment screws for the threshold and swing areas on the OA-607 T front, each area's depth angle (angle seen from side) can
be independently adjusted between -5 and +5° (respectively shallow and deep).
NOTE
Recommended detection angle setting: +5°
CAUTION
CAUTION
Adjust the areas in accordance with ANSI 156.10.
■ OA-607 T
Threshold area angle gauge
Threshold area angle screw
Threshold area (1st row)
Side view
+5°
Charts show the values in the following angle adjustment settings ;
Threshold area (1st row) : +5°
Swing area (2nd,3rd row) : +5°
A
Threshold area
(1st row)
Swing area
(2nd,3rd row)
NOTE
When the sensor system performs an initial setup to its operating environment detection areas may vary slightly from this chart.
18
Swing area angle screw
Swing area angle gauge
Swing area (2nd,3rd row)
G
H
I
J
K
L
M
N
O
-5°
A
6'7" (2000)
B
7" (186)
C
1'2" (360)
D
6" (152)
E
2'9" (840)
F
5'5" (1650)
G
B
D
H
1'11" (593)
I
3" (89)
C
E
J
3' (911)
K
1'4" (407)
F
L
4'2" (1275)
M
2'6" (770)
N
5'6" (1684)
O
3'10" (1180)
[feet,inch (mm)]
7'6" (2300)
8'2" (2500)
8" (214)
9"(233)
1'4" (414)
1'6"(450)
7" (175)
7"(190)
3'2" (966)
3'5"(1050)
6'2" (1898)
6'9"(2063)
10" (252)
2'1" (645)
2'3"(678)
6" (141)
7"(174)
3'4" (1010)
3'6"(1076)
1'8" (506)
1'11"(572)
4'8" (1428)
5'(1531)
3' (924)
3'4"(1027)
6'3" (1900)
6'8"(2042)
4'7" (1395)
5'1"(1538)

Advertisement