Optex ELITE PRO Instruction Manual
Hide thumbs Also See for ELITE PRO:

Advertisement

Quick Links

ELITE PRO
ELITE PRO2
ELITE PRO LE
Sensors for full energy and low energy automatic swing doors
Packaged combinations of swing door sensor head
OA-607 T
Swing door sensor controller
OC-907C T
Instruction manual
Contents
Manufacturer's statement..........................................................................1
Overview ...................................................................................................2
Accessories ...............................................................................................3
Part names ................................................................................................4
Installation .................................................................................................5
Wiring ......................................................................................................10
Power ON ................................................................................................13
Indicator confirmation ..............................................................................13
Settings ...................................................................................................15
Automatic settings and auto area learn ............................................................15
Dipswitch settings .............................................................................................16
Detailed settings ...............................................................................................16
Reset ................................................................................................................17
Detection area adjustment ......................................................................18
Walk test .................................................................................................19
Troubleshooting.......................................................................................19
Dimensions .............................................................................................22
Specifications ..........................................................................................22

Manufacturer's statement

Read this instruction manual carefully before use, to ensure proper operation of this product.
Failure to read this instruction manual may cause improper operation and may result in serious injury or death of a person.
The meanings of the symbols are as follows.
Failure to follow the instructions provided with this indication and improper handling may cause injury and/or
WARNING
WARNING
property damage.
Failure to follow the instructions provided with this indication and improper handling may cause death or serious
CAUTION
CAUTION
injury.
NOTE
Special attention is required to the section of this symbol.
1. Set door speeds and verify proper operation of door manufacturer's equipment prior to applying power to the sensor system.
2. Do not install the sensor where it might be directly sprayed with rainwater.
3. Verify proper wiring prior to applying power to the sensor system to prevent damage to equipment.
4. When setting the sensor's area pattern, make sure there is no traffic around the installation site.
5. Do not attempt to rebuild or repair sensor heads or control unit. Contact the address in this manual for replacement products.
6. Only use the sensor as specified in the supplied instructions.
7. Walk test the installation to verify operation is in compliance with all local laws, codes and standards of your country.
8. Upon completion of installation and adjustments, instruct the owner/operator on proper operation of the door and sensor system.
9. Identify any switches/breakers that will place the door out of service when unsafe or improper operation is identified.
5932261 FEB 2023

Advertisement

Table of Contents
loading

Summary of Contents for Optex ELITE PRO

  • Page 1: Table Of Contents

    ELITE PRO ELITE PRO2 ELITE PRO LE Sensors for full energy and low energy automatic swing doors Packaged combinations of swing door sensor head OA-607 T Swing door sensor controller OC-907C T Instruction manual Contents Manufacturer’s statement................1 Overview ....................2 Accessories ....................3 Part names ....................4...
  • Page 2: Overview

    ELITE PRO2 Package of OC-907C T × 1 and OA-607 T × 4 ELITE PRO LE Package of OC-907C T × 1 and OA-607 T × 1 Door type and connection pattern support are as below. (Illustrations show the door from above.) ■...
  • Page 3: Accessories

    Accessories Number differs by package. Number per package Part name Appearance Description ELITE ELITE ELITE PRO2 PRO LE For connecting OC-907C T and OA-607 T (1) Loop harness (via door loop), length 7'3" (2200 mm). For connection between door front/back (2) Pass-through harness (inner/outer) OA-607 T, length 8"...
  • Page 4: Part Names

    Part names ■ OA-607 T • With cover Name Connector • Without cover Dipswitches Operation indicator Function switch Mounting holes Threshold area angle screw Threshold area angle gauge Swing area angle screw Swing area angle gauge (10) Detection window (6) (7) (10) •...
  • Page 5: Installation

    Installation Install in the order of OC-907C T, OA-607 T, door loop. Below is a configuration example with the ELITE PRO. OC-907C T Step 1) Installing OC-907C T and connecting the loop harness Loop harness ■ Connect the loop harness connector 7'3" (2200 mm) to the OC-907C T. OA-607 T Step 2) Installing OA-607 T ■...
  • Page 6 ■ Step 1) Installing OC-907C T and Apply the door template to the door panel. connecting the loop harness The template top should be between 6'7" (2.0 m) and 8'2" (2.5 m) from the ground. Using the hook-and-loop fastener included as When the template is accurately positioned, align the 3/8"...
  • Page 7 Removing the cover. After fixing OA-607 T to the door, tightly fasten the Insert a flathead screwdriver into the right/left holes Silver mounting screws. on the cover bottom and push up to remove. Position OA-607 T on the other side of the door as well.
  • Page 8 For exposed wiring, use the jamb cover knockout. Fasten the door loop cover securely to the door leaf Wrap the wiring in the longer corrugated tube included with two Black mounting screws. as standard. Black × 2 Knockout Pass the loop harness taken out through the longer corrugated tube included as standard.
  • Page 9 ■ Step 4) Connecting the door front/back Install the remaining sensors similarly. OA-607 T Connect the pass through harness to the left end of the door front OA-607 T and pass it through the 3/8" (10 mm) hole. Connect the pass through harness to the right end of the door back OA-607 T.
  • Page 10: Wiring

    Wiring CAUTION CAUTION Do not turn the power on while wiring. Otherwise, electric shock or device damage may result. • Power harness Name Color Specifications Orange Power (*) 12 to 30 VDC Brown *1: Polarity free. • I/O harness Name Color Specifications Form A relay 50 V, 0.3 A (resistance load)
  • Page 11 ■ Wiring door operators from various manufacturers • Wiring example for double swing door Polarity free for all wiring Door 1 Door 2 Power 12 to 30 VDC Door controller Door controller Pink Pink Test output Test output Green Green Stall input Stall input Yellow...
  • Page 12 • Wiring example for single swing door Polarity free for all wiring Power 12 to 30 VDC Door controller Pink Test output Green Stall input Yellow Activation input White Electric strike BG output Motor Purple Activation sensor Time delay module Relay 1 Electric lock output...
  • Page 13: Power On

    ● Using the T-tap connector (male/female) included as standard Insert the wire into the Put the wire in the connector. terminal and crimp it down to secure the wire. Use the pliers to fold the Plug the terminal directly connector over the wire. into the connector.
  • Page 14 ■ OC-907C T indicator Operation indicator Interface indicator Activation output Stall output Knowing act input Motor/BG input Close switch input NOTE In both the operation indicator/interface indicator, the left column corresponds to the left-side connector and the right corresponds to the right-side connector.
  • Page 15: Settings

    Settings ■ Automatic settings and auto area learn NOTE Please check the dipswitch settings and detection area before executing. • Dipswitch (→ see “Dipswitch settings”) • Detection area (→ see “Detection area adjustment”) Execute the following with the function switch on the OA-607 T front or with the setting app. Auto configuration : E LITE PRO has an advance learning system that can recognize the following system configuration and status and set the related parameters properly and automatically for easy and quick settings.
  • Page 16: Dipswitch Settings

    ■ Dipswitch settings For automatic settings, check the “ ” mark below for the dipswitch settings for the OC-907C T and OA-607 T. ● OC-907C T Dipswitches Factory default settings Function Setting Dipsw Priority setting Wi-Fi Disable Enable Knowing act Disable Enable Test output (activation)
  • Page 17: Reset

    After connection, read the code below or connect to http://192.168.3.3/ via the web browser. This enables access to the setting screen. The indicator status is as below. Meaning Color Indicator diagram Status OA-607 T operation indicator OC-907C T operation indicator Blinking among colors Green/Blue Sensor setting via Wi-Fi...
  • Page 18: Detection Area Adjustment

    Detection area adjustment The 1st row from the door (row in diagonal line) is called the threshold area and the 2nd and 3rd rows the swing area; the depth angle for each can be set separately. With the angle adjustment screws for the threshold and swing areas on the OA-607 T front, each area’s depth angle (angle seen from side) can be independently adjusted between -5 and +5°...
  • Page 19: Walk Test

    Walk test The approach side sensor detects entrance into the area while the door is fully closed, fully open, or opening/closing and checks that the door is open or will open again. The swing side sensor detects entrance into the area while the door is fully closed or opening and checks that the door stops or creeps.
  • Page 20 Indicator Symptom Procedures Possible cause Possible countermeasure diagram Power ON Detection area has not been saved Execute auto area learn Setting by app Change the sensor position Improper wiring of activation output Verify proper wiring (Yellow wires) Area learning Improper wiring of door equipment Verify proper wiring of ON/OFF/HOLD switch error ON/OFF/HOLD switch...
  • Page 21 Indicator Symptom Procedures Possible cause Possible countermeasure diagram Improper power supply Correct power problem Improper wiring of power harness Verify proper wiring Power failure Power ON Sensor failure Contact your installer or service engineer Unlit Improper loop harness or pass through Power failure Power ON Verify proper wiring...
  • Page 22: Dimensions

    Product lineup ELITE PRO2 (OA-607 T × 4, OC-907C T × 1) : For double full energy ELITE PRO LE (OA-607 T × 1, OC-907C T × 1) : For single low energy OA-607 T : Indoors, semi-outdoors Usage location...
  • Page 23 Regarding the open source code of this product, we will distribute the source code corresponding to the open source software at the actual cost for at least 3 years after purchasing it to the individual/group who made the inquiry. Contact : OPTEX OSS information desk E-mail : oss-distribute@optex.co.jp...
  • Page 24 Contact Manufacturer OPTEX CO., LTD. North and South America Subsidiary OPTEX INCORPORATED 5-8-12, Ogoto, Otsu, Shiga, 520-0101 Japan 10741 Walker Rd. Suite 300 Cypress, CA 90630 U.S.A www.optexamerica.com Tel : +1(800)877 6656...

This manual is also suitable for:

Elite pro2Elite pro leOa-607 tOc-907c t

Table of Contents