Contents
Manufacturer's statement .........................................................................1
Overview ...................................................................................................2
Accessories ...............................................................................................2
Part names ................................................................................................4
Installation .................................................................................................5
Wiring ......................................................................................................10
Power on .................................................................................................13
Indicator confirmation ..............................................................................13
Function settings .....................................................................................15
Detection area adjustment ......................................................................17
Automatic settings and auto area learn ...................................................18
Walk test .................................................................................................19
Troubleshooting.......................................................................................19
Dimensions .............................................................................................23
Specifications ..........................................................................................24

Manufacturer's statement

Read this operation manual carefully before use, to ensure proper operation of this product.
Failure to read this operation manual may cause improper operation and may result in serious injury or death of a person.
The meanings of the symbols are as follows.
Failure to follow the instructions provided with this indication and improper handling may cause injury and/or
WARNING
WARNING
property damage.
Failure to follow the instructions provided with this indication and improper handling may cause death or serious
CAUTION
CAUTION
injury.
NOTE
NOTE
Special attention is required to the section of this symbol.
1. Set door speeds and verify proper operation of door manufacturer's equipment prior to applying power to the sensor system.
2. Do not install the sensor where it might be directly sprayed with rainwater.
3. Verify proper wiring prior to applying power to the sensor system to prevent damage to equipment.
4. When setting the sensor's area pattern, make sure there is no traffic around the installation site.
5. Do not attempt to rebuild or repair sensor heads or control unit. Contact the address in this manual for replacement products.
6. Only use the sensor as specified in the supplied instructions.
7. Walk test the installation to verify operation is in compliance with all local laws, codes and standards of your country.
8. Upon completion of installation and adjustments, instruct the owner/operator on proper operation of the door and sensor system.
9. Identify any switches/breakers that will place the door out of service when unsafe or improper operation is identified.
5932260 2022.08

Advertisement

Table of Contents
loading

Summary of Contents for Optex ELITE PRO

  • Page 1: Table Of Contents

    ELITE PRO ELITE PRO2 ELITE PRO LE Sensors for full-energy and low-energy automatic swing doors Packaged combinations of Swing Door Sensor Head OA-607 T Swing Door Sensor Controller OC-907C T Instruction Manual Contents Manufacturer’s statement .................1 Overview ....................2 Accessories ....................2 Part names ....................4...
  • Page 2: Overview

    ELITE PRO2 Package of OC-907C T × 1 and OA-607 T × 4 • Full energy doors ELITE PRO LE Package of OC-907C T × 1 and OA-607 T × 1 Loop harness Loop harness Door type and connection pattern support are as below.
  • Page 3 „ Standard accessories Number differs by package Number per package ELITE No. Part name Appearance Description ELITE ELITE PRO2 (1) Loop harness (cable between For connecting the sensor controller and OC-907C T and OA-607 T) OA-607 T (via door loop cover), length 7’3” (2200 mm) Smaller connector Larger connector...
  • Page 4: Part Names

    Part names „ OA-607 T • With cover Name • Without cover Connector Dipswitches Operation indicator Function switch Mounting holes Threshold area angle screw Threshold area angle gauge Swing area angle screw (10) Swing area angle gauge • When combined with door loop (10) Detection window Door loop cover Pass loop harness from OC-907C T through from...
  • Page 5: Installation

    Installation Install in the order of OC-907C T, OA-607 T, door loop. Below is a configuration example with the ELITE PRO. OC-907C T Step 1) Installing OC-907C T and connecting the loop harness ▪ Connect the loop harness connector Loop harness to the OC-907C T.
  • Page 6 „ Step 1) Installing OC-907C T and Paste the door template on. connecting the loop harness The template top should be between 6’7” and 8’2” from the ground. Using the hook-and-loop fastener included as stan- When the template is accurately positioned, align the 3/8” dard, attach OC-907C T to the transom.
  • Page 7 Removing the cover After fixing OA-607 T to the door, tightly fasten the Insert a flathead screwdriver into the left/right holes Silver mounting screws. on the cover bottom and push up to remove. Silver mounting screws for OA-607 T sensor head Position OA-607 T on the other side of the door as well.
  • Page 8 For exposed wiring, use the jamb cover knockout. NOTE NOTE Wrap the wiring in the longer corrugated tube includ- ed as standard. As in the figure at right, wrap the loop harness around the door loop cover to adjust its length. Knockout Fasten the door loop cover securely to the door leaf with two Black mounting screws.
  • Page 9 „ Step 4) Connecting the door front/back Install the remaining sensors similarly. OA-607 T Connect the pass through harness to the left end of the door front OA-607 T and pass it through the 3/8” (10 mm) hole. Connect the pass through harness to the right end of the door back OA-607 T.
  • Page 10: Wiring

    Wiring Wire the OC-907C T. CAUTION CAUTION Do not turn the power on while wiring. Otherwise, electric shock or device damage may result. „ OC-907C T Power harness × 1 and door controller interface × 2 (for double door left and right sides) are included. •...
  • Page 11 „ Wiring door operators from various manufacturers z Wiring (monitored door) • Wiring example for single swing door OC-907C T Power 12 to 30 VDC Polarity free for all wiring (Polarity free) Door controller Pink Test output Green Stall input Yellow Activation input Time delay module...
  • Page 12 • Wiring example for double swing door OC-907C T Door 1 Door 2 Power 12 to 30 VDC (Polarity free) Polarity free for all wiring Polarity free for all wiring Door controller Door controller Pink Pink Test output Test output Green Green Stall input...
  • Page 13: Power On

    z Using the T-tap connector (male/female) included as standard Insert the wire into the Put the wire in the connector. terminal and crimp it down to secure the wire. Use the pliers to fold the Plug the terminal directly connector over the wire. into the connector.
  • Page 14 „ OC-907C T indicator Operation indicators NOTE NOTE Left corresponds to left side connector and right to right side connector. Interface indicators Activation output indicator Stall output indicator Motor voltage/Bodyguard input indicator Knowing Act input indicator Close switch input indicator Wifi status indicator NOTE NOTE...
  • Page 15: Function Settings

    Function settings Set the OA-607 T and OC-907C T. For setting, use the dipswitches for each device or the setting app. For more detailed settings, use the setting app. „ OA-607 T For setting OA-607 T, use the dipswitch or the setting app. z Dipswitch settings (thick-bordered box): Factory default settings Function...
  • Page 16 „ Detailed settings Detailed settings can be done from a smart device browser. Set the sensor controller SW1 (priority setting) to ON (setting app priority) and the SW2 (Wi-Fi setting) to OFF (using Wi-Fi communication) (factory default). From the Wi-Fi setting screen, find the Wi-Fi name (ELITEXXXXXXXX) and connect. NOTE NOTE XXXXXXXX is the serial number of the OC-907C T.
  • Page 17: Detection Area Adjustment

    Detection area adjustment The first row from the door (row in diagonal line) is called the threshold area and the 2nd and 3rd rows the swing area; the depth angle for each can be set separately. With the angle adjustment screws for the threshold and swing areas on the OA-607 T front, each area’s depth angle (angle seen from side) can be independently adjusted between -5 and +5°...
  • Page 18: Automatic Settings And Auto Area Learn

    Execute the following with the function switch on the OA-607 T front or with the setting app. Auto configuration: ELITE PRO has an advance learning system that can recognize the following system configuration and status and set the related parameters properly and automatically for easy and quick settings.
  • Page 19: Walk Test

    „ Smart device operation Auto configuration and auto area learn can be executed from the setting app. Walk test The approach side sensor detects entrance into the area while the door is fully closed, fully open, or opening/closing and checks that the door is open or will open again. The swing side sensor detects entrance into the area while the door is fully closed or opening and checks that the door stops or creeps.
  • Page 20 Procedures Color Indicator diagram Status When installed on approach side When installed on swing side Error or warning Green Blinking (0.5 s Signal saturation (*1) generated intervals) Solid/off (0.5 s only) ANSI 500 ms OFF When solid Green during stand-by, the indicator will go off for 0.5 s when the door controller test signal is input, and then light up Green 0.5 s again...
  • Page 21 Procedures Color Indicator diagram Status Meaning Error or warning Blinking twice (0.1 s Wiring error generated interval) (0.7 s unlit) One of the wiring errors below with OC-907C T. Activation output (Yellow wire), stall output (Green wire), test input (Pink wire), BodyGuard or motor voltage input (Red wire), close switch input (White wire).
  • Page 22 Symptom Possible cause Possible countermeasures No safety on swing side OA-607 T sensor detects (solid or Improper connection of stall output (Blue Verify proper connection of stall output when door fully closed/ blinking Red indicator) (blinking: wires) from OC-907C T to activation device (Blue wires).
  • Page 23: Dimensions

    Regarding the open source code of this product, we will distribute the source code corresponding to the open source software at the actual cost for at least 3 years after purchasing it to the individual/group who made the inquiry. Contact: OPTEX OSS information desk E-mail: oss-distribute@optex.co.jp This product contains various open source software to which the following license information applies.
  • Page 24: Specifications

    Swing type automatic doors Product lineup ELITE PRO (OA-607 T × 2, OC-907C T × 1): For Double Low Energy or Single Full Energy ELITE PRO2 (OA-607 T × 4, OC-907C T × 1): For Double Full Energy ELITE PRO LE (OA-607 T × 1, OC-907C T × 1): For Single Low Energy...