Optex ELITE PRO Instruction Manual page 20

Sensors for full-energy and low-energy automatic swing doors
Hide thumbs Also See for ELITE PRO:
Table of Contents

Advertisement

Procedures
Color
Error or warning
Green
generated
Green
Orange
Orange/Green
Red
Orange
*1: Includes mounting position too low and wall or other object in detection range. The OA-607 T threshold value angle can be set at depth +5°
or less.
*2: One of the wiring errors below on the sensor controller side: Activation output (Yellow wire), stall output (Green wire), test input (Pink wire),
BodyGuard or motor voltage input (Red wire), close switch input (White wire).
*3: Connected with sensor cable, but communication is unstable. Sensor cable may be disconnected or connector insertion may be loose.
z OC-907C T operation indicator
Procedures
Color
Before initial setup
Orange
During initial setup
Orange
During background
Red/Yellow
learning
Error or warning
Green
generated
Green
Orange
Orange/Green
20
Indicator diagram Status
Blinking (0.5 s
intervals)
Solid/off (0.5 s only) ANSI 500 ms OFF
0.5 s
Blinking fast (0.1 s
intervals)
Blinking (0.5 s
intervals)
Blinking among col-
ors (0.5 s intervals)
Blinking twice (0.1 s
interval) (0.7 s unlit)
0.7 s
2 times
Blinking twice (0.1 s
interval) (0.7 s unlit)
0.7 s
2 times
Operation indicator
(Left corresponds to left side connector
and right to right side connector)
Indicator diagram Status
Blinking (0.5 s
intervals)
Blinking (0.5 s
intervals)
Blinking among col-
ors (0.1 s intervals)
Blinking (0.5 s
intervals)
Solid/off (0.5 s only) When solid Green during stand-by, the indicator will go off for 0.5 s
0.5 s
Blinking fast (0.1 s
intervals)
Blinking (0.5 s
intervals)
Blinking among col-
ors (0.5 s intervals)
When installed on approach side
Signal saturation (*1)
When solid Green during stand-by, the indicator will go off for 0.5 s
when the door controller test signal is input, and then light up Green
again
Sensor failure (self-monitoring) or sensitivity too low
Setting error (includes auto configuration incomplete (at initial startup))
Position error (includes shift to auto configuration when door is not fully
closed)
Wiring error (*2)
Communication error (*3)
Meaning
Configuration error within setting error
Auto configuration abnormally completed
Auto area learn Incomplete
When auto area learn is incomplete at activation, or has failed for some
reason
Signal saturation
when the door controller test signal is input, and then light up Green
again
Sensor failure (self-monitoring) or sensitivity too low
Setting error (includes auto configuration incomplete (at initial startup))
Position error (includes shift to auto configuration when door is not fully
closed)
When installed on swing side