Wiring

CAUTION
CAUTION
Do not turn the power on while wiring. Otherwise, electric shock or device damage may result.
• Power harness
Name
1
Power (*)
2
*1: Polarity free.
• I/O harness
Name
1
Activation output
2
3
None
4
5
Stall output
6
7
Test input
8
9
Motor/BG input
10
11
None
12
13
Knowing act input
14
15
Close switch input
16
10
Color
Orange
12 to 30 VDC
Brown
Color
I/O
Yellow
Output
-
-
Green
Output
Pink
Input
Red
Input
-
-
Purple
Input
White
Input
Specifications
Form A relay 50 V, 0.3 A (resistance load)
At power OFF: Open
At stand-by: Open, at detection: Close
-
Form A or B relay 50 V, 0.3 A (resistance load)
Set form A or B with the setting app.
When setting N.O.
At power OFF: Close
At stand-by: Open
At detection: Close
When setting N.C.
At power OFF: Close
At stand-by: Close
At detection: Open
Optocoupler voltage 5 to 30 VDC, current 6 mA max. (30 VDC) (polarity free)
Optocoupler voltage 5 to 160 VDC, 5 to 120 VAC, 60 Hz (polarity free)
-
Dry contact input
Connect push plate, etc.
Dry contact input
Connect a device recognizing fully closed status (a magnet switch, etc.).
Specifications