Vibration & temperature monitoring type (K6CM-VB)
Three-phase
power supply
Single-phase
power supply
Measurement
trigger signal
Dedicated tool
LAN
By keeping a PC or PLC continuously connected, you can monitor the state of a motor.
Note.
Even without a PC, the alarm bar of the main unit notifies you of changes of motor state.
*1. When you use an inverter to drive the motor, you may not be able to check the degradation tendency of the motor.
In the conditions below, acceleration fluctuations tend to occur more frequently.
• The frequency is stable at an inverter drive frequency of 50 Hz or higher.
• The inverter carrier frequency is stable at 12.5 KHz or higher.
Test in the actual installation environment before use.
*2. C an be used only with EIP CPU version 1.2 or higher.
Inverter *1 (measurement is also possible without an inverter)
K6CM-VBS1
(pre-amplifier)
1 m
(extendable to 100 m)
(pre-wired cable)
K6CM-VB
EtherNet/IP
Built-in EtherNet/IP port
Modbus TCP
*2
2.6 m
(pre-wired cable)
Connector
0.3 m
Sensor head
Output signal
(transistor output)
Object monitored
Tighten screw
perpendicularly
directly above
rotation shaft
(load side)
27