Venture Products Ventrac SS575 Operator's Manual & Parts Drawings page 22

Salt spreader
Table of Contents

Advertisement

15. Connect the battery/controller wire harness and
the motor/controller wire harness to the spreader
controller and route the harnesses back along the
control box mount arm and down along the roll bar.
16. Use Velcro ties to fasten both wire harnesses
to the arm of the control box mount just behind
the controller and also to fasten the harnesses
together, but not to the control box arm, about
halfway back to the roll bar.
17. Leave a small amount of slack in the wire harnesses
and use Velcro ties to fasten the harnesses to the
roll bar just below the frame mount bracket and right
above the power unit fender as shown above.
18. Connect the motor/controller harness to the
power cord on the spreader and coil the extra
wire at the corner of the right fender. Use a Vel-
cro tie to fasten both harnesses to the power unit
seat box. Fasten the coils of the motor/controller
harness together using a Velcro tie.
19. Cut the push-on connectors off the end of the
battery/controller wire harness and strip 1/4" of
insulation off the end of each wire.
20. Locate the adapter harness plug with red and black
wires. Insert the red wire from the battery/controller
harness into the butt connector on the red wire (M)
from the adapter harness and crimp in place. Insert
the black wire from the battery/controller harness
SPREADER SETUP & INSTALL KITS
into the butt connector on the black wire (N) from
the adapter harness and crimp in place.
M
21.
Slide the heat shrink tube (O) over the butt con-
nectors and use a heat gun to shrink in place.
22. If the spreader is being used without a vibrator, fold
the white and black wire with butt connectors back
along the connector and harness and tape in place.
23. Coil the extra wire of the battery/controller har-
ness inside the seat box area and use a Velcro
tie to fasten the coils together.
24. Install the 25 amp circuit breaker into slot 1 of
the rear fuse panel and the 10 amp fuse into slot
3 of the rear fuse panel.
25. Remove the cover from the power relay module
and replace both J-case fuses (P) with the sup-
plied 60 amp J-case fuses.
26.
Connect the negative battery cable to the battery.
27. Use the #10-32 x 1-1/2" screw and flange nut to
attach the tether on the spreader's power cord
cap to the plug on the power cord.
Installation is complete.
Setup - 22
O
N
P

Advertisement

Table of Contents
loading

Table of Contents