Venture Products Ventrac SS575 Operator's Manual & Parts Drawings page 16

Salt spreader
Table of Contents

Advertisement

15. Leave a small amount of slack in the wire harnesses
and use Velcro ties to fasten the harnesses to the
roll bar just below the frame mount bracket and right
above the power unit fender as shown above.
16. Coil the extra wire of the motor/controller har-
ness at the corner of the right fender and use a
Velcro tie to fasten both harnesses to the power
unit seat box. Fasten the coils of the motor/con-
troller harness together using a Velcro tie.
17. Coil the extra wire of the battery/controller har-
ness at the corner of the left fender and use a
Velcro tie to fasten to the power unit seat box.
18.
Install the circuit breaker into the fuse holder of
the positive wire as shown above.
Installation is complete.
SPREADER SETUP & INSTALL KITS
Fuse Holder
Power Unit With KW350 Cab
1. Remove the tunnel cover from the lower rear
frame of the power unit.
2. On KW350 cabs with
serial numbers 1001-
1060, mounting holes
must be drilled in the
right front cab post.
Unfasten the velcro
from the pleated canvas
and move out of the
way. Mark the post
22-5/8" up from the post
mounting plate and 1/2"
in from edge of flange.
Mark the second hole
2-1/4" up from the first
hole. Drill the mounting
holes using a 7/32" drill
bit, remove any metal
shavings, and use touch
up paint on exposed metal. Reinstall the pleated
canvas onto the cab post.
3. Install the gate cable mount bracket on the back
of the right front cab post flange using 2) #10-32
x 1/2" machine screws and flange nuts.
4. On KW350 cabs with serial numbers 1001-1060,
a mounting hole must be drilled in the dash tray of
the bottom windshield mount. Measure 2-11/16" in
from the inside of the rear lip and 5-1/2" in from
the inside of the right lip.
Setup - 16
1/2"
2-1/4"
22-5/8"
5-1/2"
2-11/16"

Advertisement