8. Install the spreader hitch onto the spreader using
4) 1/2" x 1-1/4" bolts (G) and 4) 1/2" flat washers
(H). Use Loctite 242 or equivalent thread locker
on bolts. Torque to 45 ft-lbs (61 Nm).
9.
Fasten the spreader's power cord to the hitch
frame at two places using zip ties (I).
10.
Insert the spreader hitch into the power unit's
receiver hitch tube and fasten with a 5/8" x 3"
clevis pin and a 1/8" x 2-1/2" hairpin.
CAUTION
If the power unit is equipped with a 3 point hitch,
adjust the lift arm links to position the lift arms
in the outermost position to prevent damage to
spreader if 3 point lift arms are raised accidentally.
Installation
(Power Unit without Cab)
(If power unit is equipped with cab, skip to next section)
1. Fasten the controller bracket (A) to the control
box mount bracket (B) using 2) #10-32 x 1/2"
machine screws and #10-32 flange nuts.
B
SPREADER SETUP & INSTALL KITS
H
I
I
11.
A
2. Place the nylon washers (C) on the inside of the
controller bracket.
G
3.
Install the controller bracket onto the controller
using the 1/4" bolts (D) and flat washers. Tighten
the bolts until the controller pivots with resistance.
D
4.
Insert the tabs (E) of the frame clamp bracket
into the slots of the frame mount bracket and
fasten with 3/8"x 2" carriage bolts and knobs.
Setup - 20