26.5

Description of the error code

Error code
1/3
2/1
2/2
2/3
2/4
2/5
2/6
3/1
3/2
3/3
3/4
18/4
18/7
18/8
18/9
18/10
18/11
18/12
18/13
18/14
18/15
18/16
18/17
18/18
18/19
18/20
18/21
19/1 ... 19/6
19/7 ... 19/12
19/13 ... 19/18
19/19 ... 19/24
19/25 ... 19/30
19/31 ... 19/36
19/37 ... 19/42
19/45 ... 19/50
19/51 ... 19/56
114
Description
Overload detected.
Overvoltage detected.
Undervoltage detected.
Voltage warning limit exceeded.
Voltage warning limit undershot.
Battery voltage warning limit undershot.
Voltage drop detected.
Excess temperature detected.
Low temperature detected.
Temperature warning limit exceeded.
Temperature warning limit undershot.
SD card is defective.
Removable storage present.
No access to the removable storage possible.
Configuration is being successfully managed by another device.
Configuration is NOT being successfully managed by another device.
Unable to load device configuration via the configuration provider.
At least 1 device is missing.
Bürkert Communicator is required.
Device must be replaced.
Device cannot be replaced as there are two many options present. Reduce the number
of compatible devices.
Problems when replacing device.
Problems when replacing device. Unable to write to at least 1 object.
Device replacement failed.
Device replacement completed successfully.
Configuration provider is not active as no memory card has been detected.
More than 1 configuration provider is active! Switch off the other provider functions.
Unit 1 ... Unit 6: Limit of switching cycle counter for pilot valve reached. Replace pilot
valve.
Unit 1 ... Unit 6: Maintenance limit for actuator reached.
Unit 1 ... Unit 6: Short circuit on the upper position feedback sensor unit.
Unit 1 ... Unit 6: Short circuit on the lower position feedback sensor unit.
Unit 1 ... Unit 6: Wire break on the upper position feedback sensor unit.
Unit 1 ... Unit 6: Wire break on the lower position feedback sensor unit.
Unit 1 ... Unit 6: Maintenance required for actuator (routine maintenance).
Unit 1 ... Unit 6: Switching time of the upper feedback position of a valve outside the
valid range.
Unit 1 ... Unit 6: Switching time of the lower feedback position of a valve outside the
valid range.
English