GAS CONNECTION
To make the connection, connect the mains line to
the appliance's connection pipe, fitting a shut-off tap
(A), to allow the gas supply to be cut off when neces-
sary.
Important
The tap (A), not supplied with the appliance,
must be installed in an easily accessible
position and its status (on or off) must be
obvious at a glance.This appliance shall be
installed only by authorised personnel and
in accordance with the manufacturer's in-
stallation instructions, local gas fitting reg-
ulations, municipal building codes, water
supply regulations, electrical wiring regula-
CONVERSION OF THE GAS SUPPLY
The constructor has tested the appliance with its own
mains gas, identified by the sticker applied to the
nameplate.
If the type of gas to be connected is different from that
used for testing, proceed as follows.
1 - Turn off the gas supply tap (A).
2 - Change the burner nozzle (see page 16).
3 - Change the pilot light nozzle (see page 17).
4 - Adjust the minimum setting on the gas control
valve (see page 14).
5 - If necessary, replace the primary air bushing of
the burner (see page 16).
6 - Remove the sticker from the nameplate and ap-
ply the new one to identify the gas being used.
Important
On completion of the operation, make sure
that there are no gas leaks or malfunctions.
If converting from Natural gas to Universal
LPG make sure the Natural gas regulator is
removed.
tions, AS 5601/AG 601 - Gas Installations
and any other statutory regulations.