Technical specifications
CAPACITY AND OPERATING DATA
Capacity (trays/min.)
Capacity (cutlery/min.)
Max. tray size (mm)
Cold water consumption, final rinse (litres/min.)
Steam consumption at 150–250 kPa (kg/h) *
Steam consumption at 50–140 kPa (kg/h) *
Surface temperature at a room temperature of 20° C (° C)
Sound pressure level, LPA (dB(A)) **
Sound power level, LWA (dB(A)) **
* When the machine is steam-heated.
** in accordance with EN 60 335-2-58, §ZAA.2.8 with instruments that satisfy
class 1.
Measurements of the sound pressure level on site are performed in three places
20 cm from the edges of the front at a height of 1.55 m using a microphone.
When measuring sound power level, create an imaginary measurement area
consisting of five sides at a distance of 1 m from all edges of the machine.
CONNECTION, ELECTRICALLY HEATED MACHINE
Total connected load (kW)
Main fuse 400-415 V 3N~ (A) *
Max. connection area 400-415V 3N~ (L1-L3, N, PE) (TN-S)
Cu (mm²)
Maximum short-circuit current Icu (kA)
* Other voltages on request.
CONNECTION, STEAM-HEATED MACHINE
Total connected load (kW)
Main fuse 400-415 V 3N~ (A) *
Max. connection area 400-415V 3N~ (L1-L3, N, PE) (TN-S)
Cu (mm²)
Maximum short-circuit current Icu (kA)
Steam connection (internal thread)
Condensing water connection (internal thread)
* Other voltages on request
WD-59CTS & WD-66CTS
53
Rev. (202210)
WD-59CTS WD-66CTS
25
25
75
75
530x530
530x530
5
5
50
55
50
55
35
35
63 **
63 **
83 **
83 **
WD-59CTS WD-66CTS
49.7
50.4
80
100
70
70
10
10
WD-59CTS WD-66CTS
7.7
8.4
25
35
35
35
10
10
R1"
R1"
R¾"
R¾"

Advertisement