g The [PROJECTOR SETUP] menu → [NO SIGNAL SETTING] → [NO SIGNAL LIGHTS-OUT]
f The fan will rotate to cool the projector while the no signal lights-out function is operating and the light source is turned off. Also, the power
indicator <ON (G)/STANDBY (R)> blinks slowly in green.
f When [NO SIGNAL LIGHTS-OUT] is set to anything other than [DISABLE], the following are the conditions to turn the light source back on
again from the condition that the light source has turned off by this function.
g When the signal is input
g When on-screen display such as menu screen (OSD) or input guide, a test pattern, or a warning message is displayed
g When the <POWER ON> button is pressed
g When the operation to disable the shutter function (shutter: opened) is performed, such as pressing the <SHUTTER> button
g When the operating environment temperature is around 0 °C (32 °F) and the light source is forced to turn on due to warm-up
f The no signal lights-out function is disabled in following case.
g When [BACK COLOR] is set to [DEFAULT LOGO] or [USER LOGO], and the Panasonic logo or the image registered by the user is
displayed in the projected image
[NO SIGNAL SHUT-OFF]
This is a function to automatically set the power of the projector to standby mode when there is no input signal for
specific period. The time before switching to standby can be set.
1)
Press as to select [POWER MANAGEMENT].
2)
Press the <ENTER> button.
f The [POWER MANAGEMENT] screen is displayed.
3)
Press as to select [NO SIGNAL SHUT-OFF].
4)
Press qw to switch the item.
f The items will switch each time you press the button.
[DISABLE]
[10MIN.] - [90MIN.]
Note
f The [NO SIGNAL SHUT-OFF] setting item is common with the following menu item.
g The [PROJECTOR SETUP] menu → [NO SIGNAL SETTING] → [NO SIGNAL SHUT-OFF]

[NO SIGNAL SETTING]

Set the operation of the function when there is no input signal.
[BACKUP INPUT SETTING]
Set the backup function that switches the signal to the backup input signal as seamless as possible when input
signal is disrupted.
1)
Press as to select [NO SIGNAL SETTING].
2)
Press the <ENTER> button.
f The [NO SIGNAL SETTING] screen is displayed.
3)
Press as to select [BACKUP INPUT SETTING].
4)
Press the <ENTER> button.
f The [BACKUP INPUT SETTING] screen is displayed.
5)
Press as to select [BACKUP INPUT MODE].
6)
Press the <ENTER> button.
f The [BACKUP INPUT MODE] screen is displayed.
7)
Press as to select the combination of the input and press the <ENTER> button.
Primary input
[HDMI1]
8)
Press the <MENU> button.
f The [BACKUP INPUT SETTING] screen is displayed.
Chapter 4 Settings — [PROJECTOR SETUP] menu
Disables the no signal shut-off function.
Sets the time in increments of 10 minutes.
Secondary input
[OFF]
[HDMI2]
Details
Disables the backup function.
Enables the backup function.
ENGLISH - 189