The Hardware

Extending for Special Functions

2.9
A variety of hardware for special functions are available for the MELSEC FX family.
Adapter Boards
Adapter boards are small circuit boards that are installed directly in the FX
trollers, which means that they don't take up any extra space in the switchgear cabinet.
Special Adapter
Special adapters can only be connected on the left side of a base unit of the MELSEC FX
FX
andr FX
3U
Special function modules
Up to eight special function modules can be connected on the right side of a single base unit of
the MELSEC FX family.
Training Manual GX IEC Developer
In the case of analog adapter boards, the digital values
generated from the signals coming from the analog input
adapter's two input channels are written directly to special
registers, which makes it particularly easy to process
FX1 N-2A D
them.
The output value for the analog output adapter is written by
the program also to a special register and then converted
by the adapter and sent to the output.
series.
3UC
You can install one analog special adapter to a FX
unit with 14 or 24 inputs and outputs. Up to two analog spe-
cial adapter can be mounted to a FX
60 inputs and outputs. To a FX
four analog special adapters can be connected.
Special adapters do not use any input or output points in
the base unit. They communicate directly with the base
unit via special relays and registers. Because of this, no
instructions for communication with special function mod-
ules are needed in the program.
In addition to analog modules the available special func-
tion modules include communication modules, positioning
modules and other types. Each special function module
occupies eight input points and eight output points in the
base unit.
Communication between the special function module and
the PLC base unit is carried out via the memory buffer of
the special function module with the help of FROM and TO
instructions.
FX -4 AD -T C
2N
A / D
Extending for Special Functions
, FX
or FX
1S
1N
base unit with 40 or
3G
or FX
base unit up to
3U
3UC
con-
3G
3G,
base
3G
2 - 19