Download Print this page
Mitsubishi Electric FX3U-64DP-M Installation Manual
Mitsubishi Electric FX3U-64DP-M Installation Manual

Mitsubishi Electric FX3U-64DP-M Installation Manual

Programmable controller
Hide thumbs Also See for FX3U-64DP-M:

Advertisement

Quick Links

JY997D19901E
Side
JAPANESE
A
Side
ENGLISH
B
FX
-64DP-M
3U
INSTALLATION MANUAL
Manual Number
JY997D19901
Revision
E
Date
March 2018
This manual describes the part names, dimensions, installation, and
specifications of the product. Before use, read this manual and manuals of
relevant products fully to acquire proficiency in handling and operating the
product. Make sure to learn all the product information, safety information, and
precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration
The company name and the product name to be described in this manual are the
registered trademarks or trademarks of each company.
Effective March 2018
Specifications are subject to change without notice.
2005 Mitsubishi Electric Corporation
Safety Precautions
(Read these precautions before use.)
This manual classifies the safety precautions into two categories:
and
.
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury or
physical damage.
Depending on circumstances, procedures indicated by
may also be
linked to serious results.
In any case, it is important to follow the directions for usage.
Associated Manuals
Manual name
Manual No.
Description
FX
Series
JY997D16501
Explains FX
Series PLC
3U
3U
User's Manual
MODEL CODE:
specification details for I/O, wiring,
- Hardware Edition
09R516
installation, and maintenance.
FX
Series
JY997D28701
Explains FX
Series PLC
3UC
3UC
User's Manual
MODEL CODE:
specification details for I/O, wiring,
- Hardware Edition
09R519
installation, and maintenance.
FX
/FX
/FX
/
3S
3G
3GC
FX
/FX
Series
JY997D16601
Describes PLC programming for
3U
3UC
Programming Manual
MODEL CODE:
basic/applied instructions and
- Basic & Applied
09R517
devices.
Instruction Edition
Contents explanations for wiring,
installation, specification and
FX
3U
-64DP-M
JY997D19201
allocation of BFMs, etc. for FX
User's Manual
64DP-M PROFIBUS-DP Master
Block.
GX Cofigurator-DP
Contents explanations for operation
Configuration System
of GX Configurator-DP
-
for Open Networks
Configuration System for Open
Software Manual
Networks Software.
How to obtain manuals
For the necessary product manuals or documents, consult with the Mitsubishi
Electric dealer from where you purchased your product.
Side
B
Certification of UL, cUL standards
The following product has UL and cUL certification.
UL, cUL File Number:E95239
Regarding the standards that comply with the main unit, please refer to either the FX
series product catalog or consult with your nearest Mitsubishi product provider.
Compliance with EC directive (CE Marking)
This note does not guarantee that an entire mechanical module produced in
accordance with the contents of this note will comply with the following standards.
Compliance to EMC directive and LVD directive for the entire mechanical module
should be checked by the user / manufacturer. For more details please contact the
local Mitsubishi Electric sales site.
Requirement for Compliance with EMC directive
The following products have shown compliance through direct testing (of the identified
standards below) and design analysis (through the creation of a technical construction
file) to the European Directive for Electromagnetic Compatibility (2014/30/EU) when
used as directed by the appropriate documentation.
Attention
This product is designed for use in industrial applications.
Type:
Programmable Controller (Open Type Equipment)
Models:
MELSEC FX
3U
series manufactured
from August 1st, 2005 FX
3U
-64DP-M
Standard
EN61131-2:2007
Compliance with all relevant aspects of the
standard.
Programmable controllers
EMI
- Equipment requirements and
• Radiated Emission
tests
• Conducted Emission
EMS
• Radiated electromagnetic field
• Fast transient burst
• Electrostatic discharge
• High-energy surge
• Voltage drops and interruptions
• Conducted RF
• Power frequency magnetic field
Caution for Compliance with EC Directive
 Installation in Enclosure
Programmable controllers are open-type devices that must be installed and used
within conductive control cabinets. Please use the programmable controller while
installed within a conductive shielded control cabinet. Please secure the cabinet
door to the control cabinet (for conduction). Installation within a control cabinet
greatly affects the safety of the system and aids in shielding noise from the
programmable controller.
 Control cabinet
- The control cabinet must be conductive.
- Ground the control cabinet with the thickest possible grounding cable.
- To ensure that there is electric contact between the control cabinet and its door,
connect the cabinet and its doors with thick wires.
- In order to suppress the leakage of radio waves, the control cabinet structure
must have minimal openings. Also, wrap the cable holes with a shielding cover or
other shielding devices.
- The gap between the control cabinet and its door must be as small as possible by
attaching EMI gaskets between them.
Shielding cover
Shielded cable
EMI gasket
*1
Wires
*1 These wires are used to improve the conductivity between the door and control
cabinet.
 Caution for wiring
-
3U
For noise prevention please attach at least 50 mm (1.97") of the twisted-pair cable
along the grounding plate to which the ground terminal is connected.
For details of wiring, refer to Section 3.2
1. Introduction
The FX
3U
-64DP-M PROFIBUS-DP Master Block (hereafter called "64DP-M") is a Master
(Class 1) for the PROFIBUS-DP network. The FX
3U
connected to the 64DP-M, can read input data from the DP-Slave, and write output data to
the DP-Slave. Only one 64DP-M can be connected directly to the FX
PLC's extension port, or to any other extension unit / block's right side extension port.
For details, refer to FX
*1 An FX
2NC
-CNV-IF or FX
3UC
-1PS-5V is necessary to connect to the 64DP-M
with the FX
Series PLC.
3UC
However, the 64DP-M cannot be connected to the FX
1.1 Incorporated Items
FX
-64DP-M
3U
Special Unit/Block No. label
Dust proof sheet
Manuals (Japanese version, English version)
1.2 External Dimensions and Part Namesl
[3]
[4]
[2]
[1]
Remark
4 (0.16")
43 (1.7")
[1] PROFIBUS-DP port (9-pin D-SUB Connector: #4-40unc inch screw thread)
[2] Extension cable
[3] Direct mounting hole:2 holes of 4.5 (0.18") (mounting screw: M4 screw)
[4] Status LED
LED Name Color
Lit: During normal operation
RUN
Green
TOKEN
Green Lit when token is maintained.
FROM/TO
Green Lit when accessing from PLC by FROM/TO instruction.
Unlit: During normal operation
Otherwise: An error occurs.
ERROR
Red
Lit while 24V DC power is properly supplied from FX
POWER
Green
PLC.
[5] Extension port under the top cover
[6] Name plate
[7] DIN rail mounting groove (DIN rail: DIN46277)
[8] DIN rail mounting hook
1.3 Pin configuration of PROFIBUS-DP Connector
The connector is a 9-pin D-SUB (#4-40unc inch screw thread) type, with the pin
configuration shown below.
Pin No.
3
5
6
8
1, 2, 4, 7, 9
*1
/FX
3UC
Series PLC, when
/FX
*1
series
3U
3UC
Assigned
Not assigned
-64DP-M User's Manual
3U
3UC
-32MT-LT(-2).
2. Installation
INSTALLATION
Included Item
PRECAUTIONS
1 unit
 Cut off all phases of the power source externally before starting the installation
1 sheet
or wiring work, thus avoiding electric shock or damages to the product.
1 sheet
INSTALLATION
1 manual each
PRECAUTIONS
 Use the product in the environment within the general specifications
described in the PLC main unit manual (Hardware Edition).
Never use the product in areas with dust, oily smoke, conductive dusts,
[5]
[6]
corrosive gas (salt air, Cl
impacts, or expose it to high temperature, condensation, or wind and rain.
If the product is used in such a place described above, electrical shock, fire,
malfunction, damage, or deterioration may be caused.
 Install the product securely using the DIN rail or screws.
 Install the product on a flat surface.
If the mounting surface is rough, undue force will be applied to the PC board,
[7]
thereby causing nonconformity.
 When drilling screw holes or wiring, make sure or cutting or wire debris does
not enter ventilation slits.
This may cause fire, failures, or malfunctions.
[8]
 Be sure to remove the dust proof sheet from the PLC's ventilation slits when
the installation work is completed.
9 (0.36")
Failure to do so could cause fires, equipment failures, and malfunctions.
87 (3.43")
 Fit the extension cables and communication cables securely to the
89 (3.51")
designated connectors.
Contact failures may cause malfunctions.
Dimensions: mm (inches)
 Do not touch the conductive parts of the product directly, tin order to avoid
MASS (Weight): Approx. 0.2kg (0.44 lbs)
failure or malfunction.
2.1 Connection with PLC
Only one FX
3U
extension unit/block (including special function units/blocks).
An FX
-CNV-IF or FX
2NC
the FX
Series PLC. However, the 64DP-M cannot be connected to the FX
3UC
Description
32MT-LT(-2).
For details, refer to the respective PLC manual.
For other status, refer to FX
-64DP-M
3U
User's Manual
2.2 Mounting
The 64DP-M can be mounted on a DIN rail (DIN46227) or mounted directly using
screws. For the details of installation, refer to the following manual.
For error details, refer to FX
2.2.1
Direct Mounting
3U
-64DP-M
User's Manual
The 64DP-M can be mounted with M4 screws by using the direct mounting holes.
An interval space between each unit of 1 to 2 mm (0.04" to 0.08") is necessary.
3U
2.2.2
DIN Rail Mounting
The 64DP-M can be mounted on a DIN rail (DIN46227, 35mm width).
1) Fit the upper edge of the DIN rail mounting
groove (right fig. A) onto the DIN rail.
2) Push the product onto the DIN rail.
Signal Name
Meaning
3) Connect extension cable to the main unit, I/
RXD/TXD-P
Receive/transmit-Data-P
O extension unit/block, or special function
DGND
Data Ground
unit/block of the left side.
VP
Voltage-Plus (5V, 90mA)
RXD/TXD-N
Receive/transmit-Data-N
NC
Pin not assigned
, H
S, SO
or NO
), flammable gas, vibrations or
2
2
2
2
-64DP-M can be connected to the right side of a PLC main unit or
-1PS-5V is necessary to connect to the 64DP-M with
3UC
-
3UC
FX
Series User's Manual - Hardware Edition
3U
FX
Series User's Manual - Hardware Edition
3UC
FX
Series User's Manual - Hardware Edition
3U
FX
Series User's Manual - Hardware Edition
3UC
For the mounting hole pitch information, refer to Section 1.2
1)
A
2)
FX
Series User's Manual
3U
- Hardware Edition
FX
Series User's Manual
3UC
- Hardware Edition

Advertisement

loading

Summary of Contents for Mitsubishi Electric FX3U-64DP-M

  • Page 1 1.2 External Dimensions and Part Namesl should be checked by the user / manufacturer. For more details please contact the described in the PLC main unit manual (Hardware Edition). local Mitsubishi Electric sales site. Manual Number JY997D19901 Never use the product in areas with dust, oily smoke, conductive dusts,...
  • Page 2 This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be 2) Ground the shield wire or shield of a shielded cable at one point on the PLC.
  • Page 3 This manual confers no industrial property rights or any rights of any other kind, wiring. 2) Ground the shield wire or shield of a shielded cable at one point on the PLC. nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be Maximum Number of For noise prevention please 64 slaves However, do not ground at the same point as high voltage lines.