PROFINET, Documentation
8.6.5.4
Record Signed-Integer Parameter 0x2520
Via this record, parameters of type INT8, INT16 and INT32 can be read and written. First, use the header to write the parameter ID
to the record via subindex 1. Then you can write the INT value to subindex 3 or read the complete record starting from subindex 0.
You can also write subindex 1 to subindex 3 in a single write request to write parameter ID and INT value. The written parameter ID
remains stored in the record. Restarting the sensor resets the parameter ID to the default parameter ID.
Subindex
Access
0
Read
1
Read/Write
2
Read/Write
3
Read/Write
4
Read
5
Read
6
Read
7
Read
Fig. 46 Signed integer parameter record 0x2520
optoNCDT 1900 / Profinet
Data type
Name
UINT8
Subindex 0
UINT16
Parameter ID
UINT8
Reserved
INT32
INT32 value
STRING(14)
Name of the parameter
STRING(8)
Unit of the parameter
INT32
Reserved
INT32
Reserved
Page 88