PROFINET, Documentation
Parameter
Block Header
Block Type
Block Length
Block Version High
Block Version Low
I&M1
Function Tag
Location Tag
Fig. 36 Structure I&M1 record, index: 0xAFF1, access: read-write
Parameter
Block Header
Block Type
Block Length
Block Version High
Block Version Low
I&M2
Installation date
Reserviert
Fig. 37 Structure I&M2 record, index: 0xAFF2, access: read-write
Parameter
Block Header
Block Type
Block Length
Block Version High
Block Version Low
I&M3
Descriptor
Fig. 38 Structure I&M3 record, index: 0xAFF3, access: read-write
For more information about the I&M records, please visit
https://www.profibus.com/download/PROFINET-specification
optoNCDT 1900 / Profinet
Data type
UINT16
UINT16
UINT8
UINT8
UINT8(32)
UINT8(22)
Data type
UINT16
UINT16
UINT8
UINT8
UINT8(16)
UINT8(38)
Data type
UINT16
UINT16
UINT8
UINT8
UINT8(54)
Info
0x0021
0x0038
0x01
0x00
Info
0x0022
0x0012
0x01
0x00
Installation date
Reserved
Info
0x0023
0x0038
0x01
0x00
Description text