PROFINET, Documentation
8.6.3.4

Averaging

Signal processing
Name
Comp1 type
Average 1 number of values for moving average 52001
Average 1 number of values for median
Average 1 number of values for recursive
Comp2 type
Average 2 number of values for moving average 52011
Average 2 number of values for median
Average 2 number of values for recursive
optoNCDT 1900 / Profinet
Parameter ID
Data type
52000
UINT8
UINT32
52002
UINT32
52003
UINT32
52010
UINT8
UINT32
52012
UINT32
52013
UINT32
Description
Averaging type
0 - None
2 - Moving
1 - Median
3 - Recursive
Number of values over which the average is
taken
2 - 2
...
4 - 4
2048 - 2048
8 - 8
4096 - 4096
3 - 3
7 - 7
5 - 5
9 - 9
2 - 2
5 - 5
3 - 3
...
4 - 4
32000 - 32000
Averaging type
0 - None
2 - Moving
1 - Median
3 - Recursive
Number of values over which the average is
taken
2 - 2
...
4 - 4
2048 - 2048
8 - 8
4096 - 4096
3 - 3
7 - 7
5 - 5
9 - 9
2 - 2
5 - 5
3 - 3
...
4 - 4
32000 - 32000
Access
rw
rw
rw
rw
rw
rw
rw
rw
Page 76