1F3-12 OM600 ENGINE CONTROLS
Test Procedure
1. Remove the fuel filter (1) and keep the filter not to be
damaged from running engine.
2. Remove the vacuum line (2) from ancillaries connection (3).
3. Connect the vacuum tester (4) to the ancillaries connection
(3).
4 Run the engine at idle and check vacuum pressure after 30
sec.
Standard
Notice
If out of standard, replace the vacuum pump.
5. Remove the vacuum tester.
6. Connect the vacuum line to the ancillaries connection.
7. Install the fuel filter.
Vacuum Tester 201 589 13 21 00
> 70 mbar