4892-01
(4) When applied ESP (increased pressure)
The shuttle valve and inlet valve will be open and the separation valve and outlet valve will be
closed. Then, the pump is operated.
When ESP operates while the ABS is operating, the pressure will be increased continuously until
just before the corresponding wheel gets locked.