µ-Dimension D3208 User Manual

Multizone controller/dimmer

Advertisement

Quick Links

DI-000-D3208-00A-2/13/02
1
3/6/02, 11:04 AM

Advertisement

Table of Contents
loading

Summary of Contents for µ-Dimension D3208

  • Page 1 DI-000-D3208-00A-2/13/02 3/6/02, 11:04 AM...
  • Page 2: Table Of Contents

    DESCRIPTION ... 3 SPECIFICATIONS ... 4 QUICK REFERENCE GUIDE ... 5 INSTALLATION INSTRUCTIONS ... 7 USER INTERFACE ... 13 PROGRAMMING AND OPERATION ... 14 MENU TREE ... 33 TROUBLESHOOTING ... 34 APPENDIX Latitude/Longitude Chart ... 38 DI-000-D3208-00A-2/13/02 3/6/02, 11:04 AM...
  • Page 3: Features

    SmartJack, a wall-mounted Scene Controller, and a handheld remote control (optional) • Access any of the scenes using 8 learned Infrared codes utilizing a Leviton IR Remote, Cat. No. NE210 or 32 codes with any standard IR Remote • Real Time clock retains correct time, with accuracy of 15 seconds, in absence of power typically for 2 weeks •...
  • Page 4: Introduction

    The Leviton Multizone Zone Controller/Dimmer, Cat. No. D3208, provides advanced, multi-point scene control for commercial and high-end residential lighting applications. The D3208 is a user-friendly, self-contained unit that can be used to control—at one time from the front panel—up to six zones of lighting and two auxiliary LCnet dimming or switching loads in a room or group of rooms via a series of push-buttons and “Wizard”...
  • Page 5: Description

    As part of a much larger family of digital controls and systems, the D3208 can communicate with other LCnet control stations across its high-speed serial data line.
  • Page 6: Specifications

    0°C to +40°C Software Programmer has been specified with sufficient permanent memory for 20 years to hold : - 32 Scenes - 64 Time schedules DI-000-D3208-00A-2/13/02 120VAC, 60Hz, +/-10% 24VDC @150mA 1920W/VA total 1000W/VA max. per zone 1200W/VA max. per side...
  • Page 7: Quick Reference Guide

    QUICK REFERENCE GUIDE Use this section for a quick reference for an overview of the operational features of the D3208 Multizone Controller after initial setup and programming has been completed. For more detailed features, please refer to the Programming/ Operation section of the manual.
  • Page 8 • Press the Select/Next button to save entry and return to the CONFIG WIZARD screen. • Press the Wizards button to return to the Main Screen. DI-000-D3208-00A-2/13/02 If using multiple Multizone Controllers, If using multiple Multizone Controller Use , v or SEL <CONFIG WIZARD>...
  • Page 9: Installation Instructions

    TO INSTALL: 1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING! 2. Determine location for installation of the Multizone Controller. DI-000-D3208-00A-2/13/02 INSTALLATION INSTRUCTIONS 3/6/02, 11:04 AM...
  • Page 10 Load 1 terminal means that those fixtures will be the first Zone on that Multizone Controller. The D3208 also allows you to change these zone numbers, if you desire. 6. Low-Voltage Wiring (If LCnet wiring is required): NOTES: •...
  • Page 11 10. Reinstall the Front Door Frame assembly by aligning with unit. Carefully press the frame onto unit until it snaps into position. Press all edges to ensure that it is fully seated. 11. INSTALLATION IS COMPLETE. DI-000-D3208-00A-2/13/02 INSTALLATION INSTRUCTIONS 3/6/02, 11:04 AM...
  • Page 12 INSTALLATION INSTRUCTIONS MULTIZONE CONTROLLER MOUNTING OVERLAY CONTRAST ADJUSTMENT (under Overlay) DI-000-D3208-00A-2/13/02 FIGURE 1 5 GANG BOX (4-1/2" WIDE X 2-1/2" DEEP) 4 GANG RAISED COVER (3/4" HIGH) RAISED COVER MOUNTING SCREW (4 PLACES) DIMENSIONS MULTIZONE CONTROLLER / DIMMER CONTROLLER COVER...
  • Page 13 INSTALLATION INSTRUCTIONS FIGURE 2 MULTIZONE CONTROLLER WIRING DIAGRAM 1 DI-000-D3208-00A-2/13/02 3/6/02, 11:04 AM...
  • Page 14 INSTALLATION INSTRUCTIONS FIGURE 3 MULTIZONE CONTROLLER WIRING DIAGRAM 2 Low-Voltage Wires (Plug-in Connector) LOADS 1-3 Neutral Line Ground LOADS 4-6 DI-000-D3208-00A-2/13/02 3/6/02, 11:04 AM...
  • Page 15: User Interface

    15) Cancel/Previous Button (Pgs. 14 and 18). 16) Select/Next Button (Pgs. 14 and 18). 17) Wizards/Menus Button (Pgs. 14 and 18). 18) Scene Programming and Recall Buttons (Pg. 14). 19) LCD Contrast Adjustment (under overlay). DI-000-D3208-00A-2/13/02 USER INTERFACE FIGURE 4 Scene Page Zones MAX.
  • Page 16: Programming And Operation

    Displays active Panel, Zone, Group, and Light Level information. Auxiliary Zones: Controls and displays Loads that are not directly wired to the D3208 being accessed. Function/Shortcut: Used to navigate through programming sequences and as a shortcut to access Scene Banks. NOTE: The SCENE, MAX, and OFF buttons will act on a particular group.
  • Page 17 A group is a collection of zones (i.e., loads 01-06) that is assigned a group number. A maximum of 64 groups per configuration may be programmed to the D3208. A single zone set (i.e., 01-06) may be assigned to more than one group, corresponding to different configurations. Each zone will belong to a group.
  • Page 18 NOTE: It is recommended that you use a similar layout as depicted in Figure 6 to minimize any problems while navigating through the Setup and Panel menus. NOTE: Make sure to have your layout handy (refer to Figure 6). DI-000-D3208-00A-2/13/02 FIGURE 5 Scene 2 Level Scene 3 Level...
  • Page 19 Group 3 - Panels 2 and 4 operate together Configuration 3: All rooms and panels work independently of each other Panel 1 Group 4 Group 6 Panel 3 DI-000-D3208-00A-2/13/02 PROGRAMMING AND OPERATION FIGURE 6 D320X D320X Panel 1 Panel 2...
  • Page 20 Security mode (Lock On or Lock Off). The Lock On mode allows for the option to create a password to limit access to the SCENE buttons from unauthorized personnel. DI-000-D3208-00A-2/13/02 Use , v or SEL <SETUP WIZARD> , v or SEL 1>...
  • Page 21 Press the Select/Next button to save entry and proceed. 7. When using more than one D3208: Press the Up or Down button to select the desired Panel (01-31). This setting is used to give unique addresses to each Multizone Controller if using a multiple Multizone Controller configuration.
  • Page 22 ZONE (1-8) and the Left or Right then the Up or Down buttons to select the desired PANEL (01-31). This setting provides the default information of Panel and Zone #’s. Press the Select/Next button to save entry and proceed. DI-000-D3208-00A-2/13/02 SELECT GROUP <01> PANEL 31 PANEL: 31 <INCL>...
  • Page 23 Used to setup auxiliary zones. 28. Press the Wizards button and then the Up or Down button to select the SETUP WIZARD. Press the Select/Next button to access the SETUP WIZARD. DI-000-D3208-00A-2/13/02 PROGRAMMING AND OPERATION PANEL: 31 ZONE:1 ZONE # 31-1 SELECT GROUP: 01...
  • Page 24 Daylight Savings is observed in your area. Set to the OFF position to disable setting. 7. Press the Cancel/Previous button to complete CLOCK WIZARD programming and return to the Main Screen. DI-000-D3208-00A-2/13/02 , v or SEL 4> Aux Address PANEL: 31 ZONE:7...
  • Page 25 1. Press the Wizards button and then the Up or Down button (if necessary) to select the SCENE WIZARD. Press the Select/Next button to access the SCENE WIZARD. DI-000-D3208-00A-2/13/02 PROGRAMMING AND OPERATION Use , v or SEL <SCENE WIZARD> Use , v or SEL >...
  • Page 26 5. Press the Select/Next button once to return to the SCENE WIZARD screen or press the Select/Next button and then the Wizards button to return to the Main Screen. 6. Repeat procedure to set additional banks. DI-000-D3208-00A-2/13/02 Use , v or SEL > Program Scene Select scene: 01...
  • Page 27 1. Press the Wizards button and then the Up or Down button (if necessary) to select the SCENE WIZARD. Press the Select/Next button to access the SCENE WIZARD. DI-000-D3208-00A-2/13/02 PROGRAMMING AND OPERATION Use , v or SEL <SCENE WIZARD> Use , v or SEL >Set Scene Group...
  • Page 28 Used to program the locking or unlocking of individual zones. Locking will render the Dim/Bright buttons nonfunctional. Proceed as follows: 7. Press the Select/Next button to access the ZONE WIZARD. DI-000-D3208-00A-2/13/02 , v or SEL > Exclude Zones Select scene: 01 SCENE 1...
  • Page 29 IR WIZARD – The IR WIZARD allows for the programming and remote control of up to 8 lighting scenes using a Leviton IR Remote, Cat. No. NE210 or 32 lighting scenes using any standard IR Remote as well as MAX, OFF and GROUP DIM/BRIGHT.
  • Page 30 3A.To Setup a New Timer (if there are existing Timers programmed, press the Up button to select the Add New Timer screen): Press the Select/Next button to access the Add New Timer screen. Proceed to Step 4. DI-000-D3208-00A-2/13/02 Use , v or SEL <IR WIZARD> Use , v or SEL >...
  • Page 31 Select/Next button to save entry and proceed. 7. Press the Up or Down buttons to select the desired Action (SCENE 01-32, OFF, MAX). Press the Select/Next button to save entry and proceed. DI-000-D3208-00A-2/13/02 PROGRAMMING AND OPERATION NEW TIMER T:01 DW:SMTWTFSH...
  • Page 32 • If no Holidays have been previously programmed or you want to add a new Holiday, proceed to Step 21A. • If you want to modify an existing Holiday, proceed to Step 21B. DI-000-D3208-00A-2/13/02 NEW TIMER STATUS: <ENABLE> Use , v or SEL <TIMER WIZARD>...
  • Page 33 Config Wizard. Press the Select/ Next button to access the CONFIG WIZARD. 2. Press the Select/Next button to access the Set Config screen. DI-000-D3208-00A-2/13/02 PROGRAMMING AND OPERATION Add New Holiday Press SEL to Add New Holiday...
  • Page 34 CONFIG WIZARD screen. 12. Repeat procedure for setting up additional configurations. 13. The CONFIG WIZARD is now finished. 14. Press the Wizards button to return the Main Screen. DI-000-D3208-00A-2/13/02 CONFIG 001 SELECT: 001 Use , v or SEL <CONFIG WIZARD>...
  • Page 35: Menu Tree

    MENU TREE HIGH LEVEL MENU TREE NOTE: This sequence shows the order in which each menu will appear when scrolling through the menus using the Down Function Button. DI-000-D3208-00A-2/13/02 3/6/02, 11:05 AM...
  • Page 36: Troubleshooting

    Power: 1. Check for power to EACH Multizone Controller by verifying that the LCD on the front of each unit turns ON. If all are, THE D3208 HAS PASSED THE TEST. IF NOTHING ILLUMINATES there may be a problem with the power.
  • Page 37 YOU PUSH there must be a short. • Before you replace the D3208 with a new one, make sure that the Loads you plan on attaching to the D3208 are within the limits rated by the device. The D3208 unit is rated for the following maximum capacity: 1920W/VA per unit, 1000W/VA per zone, and 1200W/VA per side.
  • Page 38 (This will automatically be the case if your installation is not accommodating combine/separate functionality for partitions.) 2. Press a scene button and make sure that the other D3208’s go to that same scene. The same scene button should light up on each unit. If this works as expected, the D3208 HAS PASSED THE TEST.
  • Page 39 3. Press the first Scene Button. 4. Press any Zone Info button and note what group the D3208 is in. Then DIM or BRIGHTEN the lights and make note of which lights are being controlled.
  • Page 40 34° N Burbank AP 34° N Chico 40° N Concord 38° N Covina 34° N Crescent City AP 42° N DI-000-D3208-00A-2/13/02 LONG STATE/CITY Downey El Cajon 86° W El Cerrito AP (S ) 86° W Escondido 85° W Eureka/Arcata AP 87°...
  • Page 41 Albany, Turner AFB 32° N Americus 32° N Athens 33° N Atlanta AP (S) 34° N Augusta AP 33° N DI-000-D3208-00A-2/13/02 APPENDIX – LATITUDE AND LONGITUDE LONG STATE/CITY Brunswick 109° W Columbus, Lawson AFB 105° W Dalton 103° W Dublin 106°...
  • Page 42 39° N Parsons 37° N Russell AP 39° N Salina 39° N Topeka AP 39° N Wichita AP 38° N DI-000-D3208-00A-2/13/02 LONG STATE/CITY KENTUCKY 86° W Ashland 86° W Bowling Green AP 87° W Corbin AP 86° W Covington AP 87°...
  • Page 43 32° N MISSOURI Cape Girardeau 37° N Columbia AP (S) 39° N Farmington AP 38° N Hannibal 40° N DI-000-D3208-00A-2/13/02 APPENDIX – LATITUDE AND LONGITUDE STATE/CITY LOING Jefferson City Joplin AP 84° W Kansas City AP 83° W Kirksville AP 85°...
  • Page 44 Lockport 43° N Massena AP 45° N Newburgh, Stewart AFB 41° N NYC-Central Park (S) 41° N NYC-Kennedy AP 41° N DI-000-D3208-00A-2/13/02 LONG STATE/CITY NYC-La Guardia AP Niagara Falls AP 71° W Olean 72° W Oneonta 71° W Oswego Co 72°...
  • Page 45 41° N Chambersburg 40° N Erie AP 42° N Harrisburg AP 40° N Johnstown 40° N Lancaster 40° N DI-000-D3208-00A-2/13/02 APPENDIX – LATITUDE AND LONGITUDE LONG STATE/CITY 84° W Meadville 83° W New Castle 83° W Philadelphia AP 84° W Pittsburgh AP 82°...
  • Page 46 40° N Provo 40° N Richfield 39° N St George Co 37° N Salt Lake City AP (S) 41° N Vernal AP 40° N DI-000-D3208-00A-2/13/02 LONG STATE/CITY VERMONT Barre 100° W Burlington AP (S) 98° W Rutland 101° W 98° W 96°...
  • Page 47 Newcastle 44° N Rawlins 42° N Rock Springs AP 42° N Sheridan AP 45° N Torrington 42° N DI-000-D3208-00A-2/13/02 APPENDIX – LATITUDE AND LONGITUDE LONG 89° W 87° W 88° W 88° W 88° W 88° W 90° W 88° W 90°...
  • Page 48 Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for two years from the purchase date.

Table of Contents