PC based programming through D3200 Setup Software and Leviton SmartJack • Access first 8 scenes using Leviton Hand-held IR Remote, Cat. No. NE210 • Learning mode for standard hand-held IR remote • Automatically turn ON/OFF lights at dusk and/or dawn (astronomical clock) •...
The Leviton Multizone Zone Controller/Dimmer, Cat. No. D3206, provides advanced, multi-point scene control for commercial and high-end residential lighting applications. The D3206 is a user-friendly, self-contained unit that can be used to control—at one time from the front panel—up to six zones of lighting in a room or group of rooms via a series of push-buttons and “Wizard”...
As part of a much larger family of digital controls and systems, the D3206 can communicate with other LCnet control stations across its high-speed fault tolerant serial data line.
Transformer, Advance Mark X Electronic Fluorescent Dimming Ballast, Neon, Cold Cathode, and non-dimming loads Testing/Code Compliance: UL Listed, CSA Certified (D3206-1) CE (D3206-2) FCC Statement: This device complies with part 15 of the FCC Rules. (D3206-1 Only) Operation is subject to the following two conditions:...
QUICK REFERENCE GUIDE Use this section for a quick reference for an overview of the operational features of the D3206 Multizone Controller. For customizing features, please refer to the Programming/Operation section of the manual. CALL SCENE: Used to choose which of the 32 programmed scenes are to be called or activated.
Page 8
Figure 4). This will page between all Included Panels programmed on the device (refer to the Panels section). • If access is not allowed to other Multizone Controllers, refer to the Setup Wizard, Step 12 to include remote panels on the network. DI-000-D3206-00B If using multiple Multizone Controllers, 11/6/03, 10:59 AM...
TO INSTALL: 1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING! 2. Determine location for installation of the Multizone Controller. DI-000-D3206-00B INSTALLATION INSTRUCTIONS 11/6/03, 10:59 AM...
Page 10
Load 1 terminal means that those fixtures will be the first Zone on that Multizone Controller. The D3206 does allows you to change these zone numbers, if you desire. 6. Low-Voltage Wiring (If LCnet wiring is required): NOTES: •...
Page 11
10. Reinstall the Front Door Frame assembly by aligning with unit. Carefully press the frame onto unit until it snaps into position. Press all edges to ensure that it is fully seated. 11. INSTALLATION IS COMPLETE. DI-000-D3206-00B INSTALLATION INSTRUCTIONS 11/6/03, 10:59 AM...
The SCENE, MAX, and OFF buttons will act on a particular group. In the Basic application this will not make a difference. However, in Advanced applications you must ensure that programming of the scene bank is the same as the zone group. DI-000-D3206-00B 11/6/03, 10:59 AM...
Page 17
A group is a collection of zones (i.e., loads 01-06) used to light a specfic area that is assigned a group number. A maximum of 64 groups may be programmed to the D3206. Each zone will belong to a group (refer to Figure 6 for example of programming).
Page 18
GROUPING EXAMPLES All 4 Panels operate together Group 2 - Panels 1 and 3 operate together Group 3 - Panels 2 and 4 operate together All rooms and panels work independently of each other DI-000-D3206-00B FIGURE 6 D320X D320X Panel 1...
Page 19
Press the Select/Next button to save entry and proceed. 4. Press the Up or Down button to select the desired Beep Mode (On or Off). Press the Select/Next button to save entry and proceed. DI-000-D3206-00B PROGRAMMING AND OPERATION Use , v or SEL <SETUP WIZARD>...
Page 20
The Lock Off mode provides full accessibility to all functional buttons. Press the Select/Next button to save entry and proceed. 8. When using more than one D3206: Press the Up or Down button to select the desired Panel (01-31). This setting is used to give unique addresses to each Multizone Controller if using a multiple Multizone Controller configuration.
Page 21
22. Press the Up or Down button to select the desired CHANNEL (1-6, X). Use this setting to change the mapping of the Channel number to the physical Load connections. Press the Select/Next button to save entry and proceed. DI-000-D3206-00B PROGRAMMING AND OPERATION Use , v or SEL 3> Zones...
Page 22
NOTE: This panel must be included on the Multizone Controller you wish to control the auxiliary device from. System – Used for factory representative to restore factory default settings. DI-000-D3206-00B SELECT TYPE: DIM ZONE# 31-1 LOAD TYPE: <INC> ZONE# 31-1 Use , v or SEL 4>...
Page 23
(United States or European Union). Press the Select/Next button to complete the CLOCK WIZARD programming and return to the Main Screen. DI-000-D3206-00B PROGRAMMING AND OPERATION , v or SEL > Info Dimensions D3206 Version 1.6.00 Period=16649 us L=061 C R=069 C Use , v or SEL <CLOCK WIZARD>...
Page 24
1. Press the Wizards button and then the Up or Down button (if necessary) to select the SCENE WIZARD. Press the Select/Next button to access the SCENE WIZARD. DI-000-D3206-00B Use , v or SEL <SCENE WIZARD> SCENE 01 Set Fade: <def>...
Page 25
5. Press the Select/Next button once to return to the SCENE WIZARD screen or press the Select/Next button and then the Wizards button to return to the Main Screen. DI-000-D3206-00B PROGRAMMING AND OPERATION , v or SEL > Program Scene...
Page 26
5. Press the Select/Next button once to return to the SCENE WIZARD screen or press the Select/Next button and then the Wizards button to return to the Main Screen. DI-000-D3206-00B Use , v or SEL <SCENE WIZARD> , v or SEL >Set Scene Group...
Page 27
NOTE: DO NOT use the Dim Scene buttons to make this adjustment. 4. Press the Select/Next button to save entry and proceed. 5. Press the Select/Next button to return the ZONE WIZARD screen. DI-000-D3206-00B PROGRAMMING AND OPERATION Use , v or SEL <SCENE WIZARD> Use , v or SEL >...
Page 28
3A.To Setup a New Timer (if there are existing Timers programmed, press the Up button to select the Add New Timer screen): Press the Select/Next button to access the Add New Timer screen. Proceed to Step 4. DI-000-D3206-00B Use , v or SEL <ZONE WIZARD> Use , v or SEL >Lock/Unlock...
Page 29
7. Press the Up or Down buttons to select the desired Action (SCENE 01-32, MAX, OFF, Auto OFF Start, and Auto Stop OFF, where applicable). Press the Select/Next button to save entry and proceed. DI-000-D3206-00B PROGRAMMING AND OPERATION NEW TIMER T:01 DW:SMTWTFSH...
Page 30
Select/Next button to save entry and proceed. 18. Repeat procedure for setting up additional holidays. 19. The TIMER WIZARD is now finished. Press the Wizards button to return the Main Screen. DI-000-D3206-00B NEW TIMER STATUS: <ENABLE> Use , v or SEL <TIMER WIZARD>...
Page 31
31. Timer Status setup is now Finished. Next Time Event – Displays the next event of the day, if programmed. 32. Press the Select/Next button to access the TIMER WIZARD. DI-000-D3206-00B PROGRAMMING AND OPERATION Use , v or SEL <TIMER WIZARD> , v or SEL >Location Setup...
Page 32
44. Press the Up or Down buttons to select the duration, in ten minute intervals, between the Sweep OFF of the loads. Press the Select/Next button to save entry and proceed. 45. Auto OFF setup is now Finished. DI-000-D3206-00B , v or SEL > Next Time Event No Timers for...
Page 33
11. Press the Up or Down button to select the desired Action to Remove (SCENE 01-32, DIM, BRIGHT, OFF, MAX, REMOVE ALL). Press the Select/Next button to save entry and proceed. DI-000-D3206-00B PROGRAMMING AND OPERATION Use , v or SEL <IR WIZARD>...
Page 34
12. Press the Select/Next button to remove the selected Action. Press the Select/Next button to save entry and proceed. 13. Repeat procedure for removal of additional commands. 14. Press the Wizards button to return the Main Screen. DI-000-D3206-00B Code Removed 11/6/03, 11:00 AM...
MENU TREE HIGH LEVEL MENU TREE NOTE: This sequence shows the order in which each menu will appear when scrolling through the menus using the Down Function Button. DI-000-D3206-00B 11/6/03, 11:00 AM...
Power: 1. Check for power to EACH Multizone Controller by verifying that the LCD on the front of each unit turns ON. If all are, THE D3206 HAS PASSED THE TEST. IF NOTHING ILLUMINATES there may be a problem with the power.
Page 37
• Before you replace the D3206 with a new one, make sure that the Loads you plan on attaching to the D3206 are within the limits rated by the device. The D3206 unit is rated for the following maximum capacity: 1920W/VA per unit, 1000W/VA per zone, and 1200W/VA per side.
Page 38
1. First make sure all attached devices are in a single group. 2. Press a scene button and make sure that the other D3206’s go to that same scene. The same scene button should light up on each unit. If this works as expected, the D3206 HAS PASSED THE TEST.
Page 39
Burbank AP 34° N Chico 40° N Concord 38° N Covina 34° N Crescent City AP 42° N DI-000-D3206-00B APPENDIX – LATITUDE AND LONGITUDE LONG STATE/CITY Downey El Cajon 86° W El Cerrito AP (S ) 86° W Escondido 85° W Eureka/Arcata AP 87°...
Page 40
27° N GEORGIA Albany, Turner AFB 32° N Americus 32° N Athens 33° N Atlanta AP (S) 34° N Augusta AP 33° N DI-000-D3206-00B LONG STATE/CITY Brunswick 109° W Columbus, Lawson AFB 105° W Dalton 103° W Dublin 106° W Gainsville 104°...
Page 41
39° N Parsons 37° N Russell AP 39° N Salina 39° N Topeka AP 39° N Wichita AP 38° N DI-000-D3206-00B APPENDIX – LATITUDE AND LONGITUDE LONG STATE/CITY KENTUCKY 86° W Ashland 86° W Bowling Green AP 87° W Corbin AP 86°...
Page 42
Tupelo 34° N Vicksburg Co 32° N MISSOURI Cape Girardeau 37° N Columbia AP (S) 92° W Farmington AP 38° N DI-000-D3206-00B LOING Hannibal STATE/CITY Jefferson City 84° W Joplin AP 83° W Kansas City AP 85° W Kirksville AP 86°...
Page 43
43° N Massena AP 45° N Newburgh, Stewart AFB 41° N NYC-Central Park (S) 41° N NYC-Kennedy AP 41° N DI-000-D3206-00B APPENDIX – LATITUDE AND LONGITUDE LONG STATE/CITY NYC-La Guardia AP Niagara Falls AP 71° W Olean 72° W Oneonta 71°...
Page 44
Butler 41° N Chambersburg 40° N Erie AP 42° N Harrisburg AP 40° N Johnstown 40° N Lancaster 40° N DI-000-D3206-00B LONG STATE/CITY 84° W Meadville 83° W New Castle 83° W Philadelphia AP 84° W Pittsburgh AP 82° W Pittsburgh Co 83°...
Page 45
Provo 40° N Richfield 39° N St George Co 37° N Salt Lake City AP (S) 41° N Vernal AP 40° N DI-000-D3206-00B APPENDIX – LATITUDE AND LONGITUDE LONG STATE/CITY VERMONT Barre 100° W Burlington AP (S) 98° W Rutland 101°...
Page 46
44° N Rawlins 42° N Rock Springs AP 42° N Sheridan AP 45° N Torrington 42° N For additional Time Zone information, go to Leviton’s website at: www.leviton.com/d3200 DI-000-D3206-00B LONG 89° W 87° W 88° W 88° W 88° W 88°...
Page 48
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for two years from the purchase date.
Need help?
Do you have a question about the D3206 and is the answer not in the manual?
Questions and answers