Rice Lake 150-10-7 Technical Manual

Rice Lake 150-10-7 Technical Manual

Digital physician scale floor-level
Hide thumbs Also See for 150-10-7:

Advertisement

Quick Links

150-10-7
Digital Physician Scale Floor-Level
Software Version 11525
Technical Manual
August 18, 2022
PN 132098 Rev C

Advertisement

Table of Contents
loading

Summary of Contents for Rice Lake 150-10-7

  • Page 1 150-10-7 Digital Physician Scale Floor-Level Software Version 11525 Technical Manual August 18, 2022 PN 132098 Rev C...
  • Page 2 All information contained within this publication is, to the best of our knowledge, complete and accurate at the time of publication. Rice Lake Weighing Systems reserves the right to make changes to the technology, features, specifications and design of the equipment without notice.
  • Page 3 Established a revision history; formatted content to match other medical manuals; software version 11525 Table i. Revision Letter History Technical training seminars are available through Rice Lake Weighing Systems. Course descriptions and dates can be viewed at www.ricelake.com/training or obtained by calling 715-234-9171 and asking for the training department.
  • Page 4: Table Of Contents

    7.0 Specifications ............... . . 21 Rice Lake continually offers web-based video training on a growing selection of product-related topics at no cost.
  • Page 5: Introduction

    Introduction Introduction The 150-10-7 digital physician scale is efficiently designed to provide accurate, reliable and repeatable weight measurements. The large stand alone indicator can be placed on a table or floor and has a sturdy built-in bracket for wall mounting.
  • Page 6: Safety

    Do not operate or work on this equipment unless this manual has been read and all instructions are understood. Failure to follow the instructions or heed the warnings could result in injury or death. Contact any Rice Lake Weighing Systems dealer for replacement manuals.
  • Page 7: Assembly

    Unpacking Place the unopened box in an open area that has ample room for unpacking the scale. If parts were damaged in shipment, notify Rice Lake Weighing Systems and the shipper immediately. Parts contained in the shipping box include: • Scale base and indicator •...
  • Page 8: Power Connection

    Power Connection An optional AC power adapter can be used when a power outlet is available. Only use power adapters supplied by or purchased from Rice Lake Weighing Systems. The use of a power IMPORTANT adapter not from Rice Lake Weighing Systems voids the warranty.
  • Page 9: Scale Operation

    Adjusts height input (0.5 in/0.5 cm) while in BMI mode Down Arrows Adjusts the value of the flashing digit/number Adjusts height input (0.5 in/0.5 cm) while in BMI mode Table 3-1. Key Functions © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 10: Weighing

    150-10-7 Digital Physician Scale Weighing Use the following steps to weigh. to turn on the scale. 0.0 prompts along with ZERO on the display. 1. Press 2. When the patient is placed on the scale, the display shows the weight of the patient. The LOCK annunciator is on in the upper display and beeps to indicate the end of the weighing process.
  • Page 11: Kg Mode

    5. Press ENTER 6. The BMI value and BMI annunciator are shown on the display. Press to return to the Weighing mode and the CLEAR BMI function will be turned off. © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 12: Troubleshooting

    150-10-7 Digital Physician Scale Troubleshooting Refer to the following table to check and correct any failure before contacting service personnel. Symptom Possible Cause Corrective Action Scale does not turn on Dead batteries Replace batteries or connect to AC power Faulty electrical outlet...
  • Page 13: Configuration

    . The next parameter displays ENTER • When all parameters selections/values are correct, SAVE displays • Press . DONE displays. ENTER • Press to save settings and return to weigh mode. ENTER © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 14: Configuration Mode

    150-10-7 Digital Physician Scale Configuration Mode Use the following steps to enter into Configuration mode. 1. Ensure the scale is turned off. . Continue to hold both keys until Id appears. 2. Turn the scale on by simultaneously pressing ENTER The unit cycles through its startup function and continues to display the software version.
  • Page 15: Programming Mode Menu

    3. Press BMI key to move to the left. 4. Use the Up/Down arrow keys to increment/decrement numbers. 5. When done, press ENTER key to move to next parameter (ASTART). Table 4-1. Configuration Mode Menu © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 16 150-10-7 Digital Physician Scale Parameter Description Choices Steps ASTART Weight process start limit — Maximum (full Value (2.0) The display toggles between a numeric value and ASTART; capacity)/10; Determine when the weight If you do not want to change this value, press the BMI key to move to the algorithm starts (when the “----”...
  • Page 17 OP7 - Bat type — (0=dry batteries, 1=rechargeable batteries) OP8 — OIML mode - (0=disable, 1=enable Press the BMI key to cycle back to the top level menu choices, ie: PROG/CALIB/DEF/DONE Table 4-1. Configuration Mode Menu (Continued) © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 18: Default Menu

    150-10-7 Digital Physician Scale Default Menu The default menu is used to return the scale back to its factory settings and is shown below. DONE PROG CALIB TEST Figure 4-4. Default Menu Use the following steps to return the settings back to their factory default.
  • Page 19: Test Menu

    Value Displays the current software version Value Displays the current battery level VALUE Value Displays the actual value Value Displays the actual raw counts of the scale Table 4-2. Test Menu © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 20: Communication

    The unit comes with an RS-232 port that enables weight data to be transmitted to other equipment, such as a computer or printer. The RS-232 cable with DB-9 connector (PN 100719) is available from Rice Lake Weighing Systems. That connection is shown in USB Connection section.
  • Page 21: Communication Protocols

    Example: <ESC><CUOM=m><ESC><E sets the unit of measurement Table 5-3. ESC Characters Name of Control Identifier Unit Unit of Measure (metric or constitutional) c (m or c) Table 5-4. Scale Global Values and Identifiers © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 22: Maintenance Protocol

    150-10-7 Digital Physician Scale Samples of Escape Protocol Examples of what is sent to the computer from the scale. direction of communication <SCALE> <PC> <SCALE> <PC> <ESC> R <ESC> W0210.9 <ESC> Nm <ESC> E <ESC>R <ESC>E Reading Reading Unit of Measure...
  • Page 23: Usb Connection

    5. With weight on the scale, press and hold the Print button on the indicator for three seconds. The patient’s weight is sent to the PC. Figure 5-5. Patient Weight Displayed © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 24: Maintenance

    150-10-7 Digital Physician Scale Maintenance The following section provides instructions for maintaining and cleaning the unit. Do not immerse the scale in cleaning or other liquid solutions. IMPORTANT Do not use Isopropyl alcohol or other solutions to clean the indicator display surface.
  • Page 25: Specifications

    14.7 in W x 14.7 in L x 3 in H (37.5 cm W x 37.5 cm L x 7.6 cm H) Certifications and Approvals E113986 Complies with ANSI/AAMI ES60601-1:2005/A2:2010/(R)2012 CAN/CSA-C22.2 No. 60601-1:14 © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 26 150-10-7 Digital Physician Scale www.RiceLake.com Visit our website...
  • Page 28 © Rice Lake Weighing Systems Specifications subject to change without notice. 230 W. Coleman St. • Rice Lake, WI 54868 • USA U.S. 800-472-6703 • Canada/Mexico 800-321-6703 • International 715-234-9171 • Europe +31 (0)26 472 1319 PN 132098 Rev C August 18, 2022 www.ricelake.com...

Table of Contents