Rice Lake 150-10-7 Operation Manual

Rice Lake 150-10-7 Operation Manual

Digital floor level scale
Hide thumbs Also See for 150-10-7:

Advertisement

Quick Links

150-10-7
Digital Floor Level Scale
Software Revision 114 54
Operation Manual
March 9, 2020
PN 131994 - Rev B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 150-10-7 and is the answer not in the manual?

Questions and answers

Summary of Contents for Rice Lake 150-10-7

  • Page 1 150-10-7 Digital Floor Level Scale Software Revision 114 54 Operation Manual March 9, 2020 PN 131994 - Rev B...
  • Page 2 All information contained within this publication is, to the best of our knowledge, complete and accurate at the time of publication. Rice Lake Weighing Systems reserves the right to make changes to the technology, features, specifications and design of the equipment without notice.
  • Page 3: Table Of Contents

    8.0 Limited Warranty ............... 12 Technical training seminars are available through Rice Lake Weighing Systems.
  • Page 4 150-10-7 Digital Floor Level Scale Rice Lake continually offers web-based video training on a growing selection of product-related topics at no cost. Visit www.ricelake.com/webinars www.RiceLake.com Visit our website...
  • Page 5: Introduction

    Introduction The Rice Lake Digital Floor Level Scale is efficiently designed to provide accurate, reliable and repeatable weight measurements. The large stand alone indicator can be placed on a table or floor and has a sturdy built-in bracket for wall mounting.
  • Page 6: Safety

    LO Bat as possible. Only use power adapters supplied by or purchased from Rice Lake Weighing Systems. The use of a power adapter not from Rice Lake Weighing Systems voids the warranty. To avoid cross contamination, the scale should be cleaned regularly.
  • Page 7: Scale Assembly

    • AA batteries (6) Repacking If the Rice Lake Digital Floor Level Scale must be returned any reason, it must be properly packed with sufficient packing materials in the original carton. Whenever possible, use the original carton when shipping the scale back.
  • Page 8 Figure 2-2. Only use power adapters supplied by or purchased from Rice Lake Weighing Systems. The use of a power adapter not from Rice Lake Weighing Systems voids the warranty. Connect the optional AC...
  • Page 9: Scale Operation

    Scale Operation Scale Operation The Rice Lake Digital Floor Level Scale display has various front panel keys as shown in Figure 3-1. Figure 3-1. Rice Lake Digital Floor Level Scale Front Panel Display Keys Key Descriptions Table 3-1 describes each of the key functions.
  • Page 10: Weighing

    Used to adjust height input (0.5 in/0.5 cm) while in BMI mode. Adjusts the value of the flashing digit/number. Table 3-1. Rice Lake Digital Floor Level Scale Key Functions The keys on the front panel display are very sensitive so only a gentle pushing motion is required.
  • Page 11: Toggle Tare

    6. The BMI value and BMI annunciator is shown on the display. Press the key to return to the weighing mode or CLEAR step off the scale and the BMI function will be turned off. © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 12: Rs-232 Communication

    6-01.0 FT PATIENT BMI 28.4 USB Connection The Rice Lake Digital Floor Level Scale has the capability of connecting to a PC using a USB connection and a USB cable (not included). That connection location is shown in Figure 4-1.
  • Page 13: Troubleshooting And Testing

    Unstable weight. Cannot calibrate Check the load cells’ mechanical surroundings and see that nothing touches them and that the cables are properly welded Damaged load cell cable Replace load cell cable Figure 5-1. Troubleshooting © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 14: Maintenance

    150-10-7 Digital Floor Level Scale Maintenance The following section provides instructions for maintaining and cleaning the Rice Lake line of scales. Maintenance operations other than those described in this section should be performed by qualified service personnel. Basic Maintenance Before the first use of the scale and after periods of non-use, check the scale for proper operation and function. If the scale does not operate correctly, contact qualified service personnel.
  • Page 15: Specifications

    Capacity and Graduation Floor Level Scale 550 lb (250 kg) 0.2 lb (0.1kg) Certifications and Approvals RoHS Compliant Dimensions Platform Dimensions 14.5 in W x 14.5 in L x 3 in H © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 16: Limited Warranty

    150-10-7 Digital Floor Level Scale Limited Warranty Rice Lake Weighing Systems (RLWS) warrants that all RLWS equipment and systems properly installed by a Distributor or Original Equipment Manufacturer (OEM) will operate per written specifications as confirmed by the Distributor/OEM and accepted by RLWS.
  • Page 18 Specifications subject to change without notice. Rice Lake Weighing Systems is an ISO 9001 registered company. 230 W. Coleman St. • Rice Lake, WI 54868 • USA U.S. 800-472-6703 • Canada/Mexico 800-321-6703 • International 715-234-9171 • Europe +31 (0)26 472 1319...