Symbol Definitions

=
CR/LF (carriage return/line feed) (hex 0D 0A)
]
=
Carriage return (no line feed, hex 0D) (For URL-
}
encoded [web browser] commands, use the
pipe character, | , instead.)
=
Space character
|
=
Pipe (vertical bar) character
*
=
Asterisk character (which is a command
character, not a variable)
E
=
Escape key (hex 1B) (Use W instead of
for URL-encoded commands used in web
browsers.)
=
Specific port number or relay number (01-99)
X!
Serial ports:
01 = COM1 port 09 = IR/serial port 1
02 = COM2 port 10 = IR/serial port 2
03 = COM3 port 11 = IR/serial port 3
04 = COM4 port 12 = IR/serial port 4
05 = COM5 port 13 = IR/serial port 5
06 = COM6 port 14 = IR/serial port 6
07 = COM7 port 15 = IR/serial port 7
08 = COM8 port 16 = IR/serial port 8
Relay ports:
01 = Relay port 1 01 = I/O port 1
02 = Relay port 2 02 = I/O port 2
03 = Relay port 3 03 = I/O port 3
04 = Relay port 4 04 = I/O port 4
05 = Relay port 5
06 = Relay port 6
07 = Relay port 7
08 = Relay port 8
Switched power output ports:
01 = power port 1
02 = power port 2
03 = power port 3
04 = power port 4
00 = reserved or all ports
NOTE: Port numbers are two ASCII
characters (two bytes). For example,
port 1 is represented as 01.
In either method, {Data} = data that will be directed to a specified port and must
be hex encoded if non-alphanumeric.
NOTE: If you make adjustments, it takes up to 1 minute 40 seconds
(100 seconds) for the data in the IPCP RAM to be saved to flash memory.
Do not remove power during that period.
E
IR/serial ports:
Flex I/O ports:
=
Command data section.
X@
NOTE: For web encoding only:
data will be directed to the specified
port and must be encoded (URL
encoding) if it is
non-alphanumeric. Change any
non-alphanumeric character (%, +,
}
, and the like) within the data section
into the corresponding hexadecimal
equivalent, %xx, where xx represents
the two-character hex byte.
For example, a space (hex: 20) would
be encoded as %20 (hex: 25 32 30)
and a plus sign (hex: 2B) would be
encoded as %2B or hex 25 32 42.
X#
=
Greenwich Mean Time (GMT) offset value
(-12.00 to +14.00) represents the time
difference in hours and minutes (+/-hh:mm)
relative to Greenwich, England. The leading
zero is optional. For example, 5:30 = 05:30.
Do not use a plus (+) sign if the GMT offset is
positive.
X%
=
On/off status
0 = off/disable
1 = on/enable
X1!
=
Version (typically listed to two decimal places;
for example, x.xx)
X1@
=
IPCP 505 unit name. The name is a text
string of up to 24 characters drawn from the
alphabet (A-Z), digits (0-9), and minus sign/
hyphen (-). No blank or space characters are
permitted as part of a name. No distinction is
made between upper and lower case. The first
character must be a letter. The last character
must not be a minus sign or hyphen.
X1#
=
Local date and time format
Set format (MM/DD/YY-HH:MM:SS).
Example: 01/18/05-10:54:00.
Read format (day of week, date month
year HH:MM:SS).
Example: Tue, 13 Jun 2011 18:19:33
X1$
=
IP address (xxx.xxx.xxx.xxx). Leading
zeros in each of the four fields are optional
in setting values, and they are suppressed in
returned values.IPCP 505 default address:
192.168.254.254.
=
E-mail domain name; for example,
X1%
extron.com
IPCP 505 • SIS Programming and Control
|
,