The Extron IPCP Pro PCS1 IP Link
Ethernet connection into AV systems to allow users to remotely control and monitor
AV equipment, including display devices and switchers. The IPCP Pro PCS1 features a
controllable, 100-240 VAC, 50-60 Hz, AC power outlet for remote power management of
a connected device. A 10 amp circuit breaker provides overcurrent protection.
The AC power button, located on the front panel, allows manual control of
the AC power output port. A front panel security lockout mode (Executive
Mode) can be used to disable the button if the unit is installed in an
unsecured environment where access is undesirable.
The IPCP Pro PCS1 includes an embedded web server, a bidirectional
serial port, an IR/serial port, digital I/O, and a LAN port for use in
applications that require control and monitoring of multiple devices within an AV system. It also includes an Extron eBUS
which allows a variety of eBUS devices to be connected to a single control processor. eBUS devices include an array of button
panels and power and signal hubs. eBUS devices are automatically recognized by the control processor and can be added or
removed at any time.
To discover and manage the IPCP Pro control processor and other Extron control products, use Extron Toolbelt
Configure the control processor using Extron Global Configurator
or Global Configurator Plus [GC Plus]), or program the control processor using Extron Global Scripter
seamlessly with Extron GlobalViewer
control processors support multiple TouchLink
applications are available at www.extron.com.
This guide provides instructions for an experienced installer to install an IPCP Pro PCS1 control processor and to create a basic
configuration.
CAUTION:
This product is intended for indoor use only.
ATTENTION :
Ce produit est exclusivement adapté à un usage intérieur.
NOTE:
The IPCP Pro PCS1 is intended to be used with Extron Electronics products only.
Setup Checklist: How to Proceed With Installation
ATTENTION:
• Installation and service must be performed by experienced personnel.
• L'installation et l'entretien doivent être effectués par du personnel expérimenté.
Get Ready
Familiarize yourself with the features of the control processor (see
Features
on page 4) and of any TouchLink Pro touchpanels that will be part of the system.
Download and install the latest version of the following:
Toolbelt software — for discovering the control processor and other control products on the network, for managing
core settings, and for upgrading firmware when needed.
Global Configurator (GC) software — for configuring the control system.
Global Scripter software — for programming the control processor (as an alternative to GC)
GUI Designer software — for designing layouts for Extron TouchLink Pro touchpanels and third party touch interfaces
IP Link Pro device drivers — for use with GC, to make control of AV devices possible
All are avail able from
Obtain network information for the unit from the network administrator. You need the following details for each IP Link Pro device:
DHCP client setting (on or off)
Device (IPCP Pro, TouchLink Pro, IPL Pro) LAN IP address
Write down the MAC address of each IP Link Pro device to be used.
Obtain model names and setup information for devices the IPCP will control.
Pro Power and Device Control Processor integrates
®
Enterprise (GVE) software and Extron Control apps for remote control applications. These
®
 Pro touchpanel interfaces over a standard Ethernet network. The software
®
www.extron.com
(see
Locating Software, Firmware, and Driver Files on the Extron Website
®
software (Global Configurator Professional [GC Professional]
Front Panel Features
on page 4,
Subnet mask
Gateway IP address
port,
®
software.
®
 (GS). The IPCP integrates
®
Rear Panel
on page 9).
Username
Passwords
1

Advertisement

Table of Contents
loading

Summary of Contents for Extron electronics IPCP Pro PCS1

  • Page 1 ATTENTION : Ce produit est exclusivement adapté à un usage intérieur. NOTE: The IPCP Pro PCS1 is intended to be used with Extron Electronics products only. Setup Checklist: How to Proceed With Installation ATTENTION: • Installation and service must be performed by experienced personnel.
  • Page 2 IPCP Pro PCS1 • Setup Guide (Continued) … Each control processor comes with a factory-installed Secure Sockets Layer (SSL) security certificate. If you intend to install a different SSL certificate, contact your IT department to obtain the certificate or for instructions on how to obtain one.
  • Page 3: Network Communication Setup

    … Save the project. … Build and upload the system configuration to the control processor. Test and Troubleshoot … Test the system (see the IPCP Pro User Guide for an outline of the system testing procedure). … Make adjustments to wiring or configuration as needed. Network Communication Setup Network setup is essential prior to configuration.
  • Page 4: Panels And Locations Of Features

    (appliance inlet) of the connected equipment. The IPCP Pro PCS1 can be configured (using Global Configurator or Global Scripter) to monitor the power output condition and to alert users in the event of a power fault interruption. The IPCP Pro PCS1 can be set up to monitor the circuit breaker and also the current load at the switched AC power output port.
  • Page 5: Cabling And Features

    • Veillez à toujours utiliser le câble d’alimentation fourni avec l’unité. • Should you need to use a different power cord, consult Extron Electronics prior to using the cord. • Si vous devez utiliser un autre câble d’alimentation, contactez Extron Electronics avant d’utiliser ce câble.
  • Page 6: Control, Bidirectional - Serial (Com)

    IPCP Pro PCS1 • Setup Guide (Continued) Control, Bidirectional — Serial (COM) Rear Panel Front Panel Serial (COM) Port IPCP 3-pole COM Select protocol via software. (RS-232) COM port default protocol: Tx Rx • 9600 baud NOTE: The 3-pole R/ S •...
  • Page 7: Control, Unidirectional - Digital I/O

    Control, Unidirectional — Digital I/O Rear Panel Front Panel Digital I/O (digital input/output) Con gure each port as a digital input or output, with or without +5 VDC pull-up. Digital I/O Use these ports to: eB U S BU S LEDs •...
  • Page 8: Reset Modes: A Brief Summary

    IPCP Pro PCS1 • Setup Guide (Continued) EBDB MINI eBUS Connections eBUS DISTRIBUTION HUB Rear Panel • Connect up to four (4) eBUS devices to the (or use EBDB Mini eBUS Distribution Hub. an EBDB • Wire the connectors the same at both ends.
  • Page 9: Obtaining Control Drivers

    Resources Obtaining Control Drivers Extron provides an extensive selection of device drivers available on the Extron website. If the system requires a control driver that is not already available, you can request a new serial (RS-232), IR, or Ethernet driver from Extron. The IPCP Pro PCS1 does not support IR learning.
  • Page 10: Overall Configuration Procedure For The Control Processor

    For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the Extron Safety and Regulatory Compliance Guide on the Extron website. 68-2438-53 Rev. A © 2018 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com 10 18...

Table of Contents