Hyundai N700E Instruction Manual page 130

Hide thumbs Also See for N700E:
Table of Contents

Advertisement

N700E INSTRUCTION MANUAL
12 mS Minimum
RS
Relay
Alarm
30mS
Danger: *When Reset is asserted to clear the fault, if the RUN command is executed by FW/RV terminal set,
the motor will immediately run to the speed. Be sure to set the RS after RUN command is disconnected in
order to prevent any injury
Caution: *If longer than 4 second is continued to be ON, E60, communication error will be displayed. Reset
by disconnect RS terminal to OFF or press STOP/RESET Key and resume VFD operation to normal.
Set 15:
Set 16:
Set 17:
Code
Set Value
A02
C01
C02
C03
C07
C08
C09
Set 18:
Set 19:
Code
Set Value
A02
A01
C01
C02
C04
C07
C08
Start (STA)
3 Wire Run/Stop Application
Keep (STP)
Forward / Reverse (F/R)
1
Run Command by Terminal Input
15
Set Terminal 1 to STA Operation
16
Set Terminal 2 to STP Operation
17
Set Terminal 3 to F/R Operation
0
FW Operation: Terminal 1 to Normal Open
When shorted(Closed): FW Run, When Open: FW Stop
0
FW Operation: Terminal 2 to Normal Open
0
FW Operation: Terminal 3 to Normal Open
Remote Control Up (UP)
Remote Control Down (DOWN)
1
Run Command by Terminal Input
Frequency Setting
18
Set Terminal 1 to UP Operation
19
Set Terminal 2 to Down Operation
1
Set Terminal 3 to F/R Operation
0
FW Operation: Terminal 1 to Normal Open
When shorted(Closed): FW Run, When Open: FW Stop
0
FW Operation: Terminal 2 to Normal Open
RS
6
5
4
CM1
Description
SW3
CM1
6
5
4
Description
3-57
FW
3
2
1
P24
Stop Switch
SW2
(N.C)
Run Switch
SW1
(N.O)
3
2
1
P24
F/R
STP
STA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents