Hyundai N700E Instruction Manual page 117

Hide thumbs Also See for N700E:
Table of Contents

Advertisement

N700E INSTRUCTION MANUAL
Analog output (DC voltage)
C18 (FM Output selection)
Set "C18=4" display calculated torque value (-150%~+150%) by analog output.
(※ C18 = 0~3 are the same as existed function)
Analog output (current)
C25 (AM Output selection)
Set "C25=4" display calculated torque value (-150%~+150%) by analog output.
(※ C25 = 0~3 are the same as existed function)
Special parameter: Calculated torque read frame by Modbus
- CMD : 03 (Read)
- Parameter : 10 (Calculated Torque)
TX
RX
※This document are written by result of test bench.
Field engineer should be tuned for each field situation by consider above case study.
FM output
0V
5V
10V
AM output
4mA
12mA
20mA
Communication Number
01
Communication Number
01
Torque
-150%
0%
+150%
Torque
-150%
0%
+150%
CMD
Parameter
03
000A
CMD
Byte Quantity
03
02
3-44
Data Quantity
CRC
0001
2byte
Data
CRC
Torque value
2byte