VERSION 12/2018
8.2

MAINTENANCE

8.2.1 MAINTENANCE PERSONNEL

Maintenance work should be undertaken regularly and carefully by qualified and trained
personnel. They should be informed of specific hazards during their training.
The following hazards may arise during maintenance work:
– risk to health from inhaling solvent vapors,
– use of unsuitable tools and aids.
An authorized person must ensure that the device is checked for being in a reliable state
after maintenance work is completed.

8.2.2 MAINTENANCE INSTRUCTIONS

DANGER
Incorrect maintenance/repair!
Danger to life and equipment damage.
Only a WAGNER service center or a suitably trained person may carry out repairs and
replace parts.
Use only WAGNER original spare parts and accessories.
Only repair and replace parts that are listed in the "Spare parts" chapter and that are
assigned to the unit.
Before all work on the device and in the event of work interruptions:
– Relieve the pressure from the spray gun, high-pressure hoses and all devices.
– Secure the spray gun against actuation.
– Switch off the energy and compressed air supply.
– Disconnect the control unit from the mains.
Observe the operating and service manual for all work.
Prior to Maintenance
– Flush and clean the system.
– Interrupt the air supply.
After maintenance
− Carry out safety checks in accordance with Chapter 8.2.3.
− Put the system into operation and check for leaks as described in Chapter 6.8.
− Have the system checked for safe condition by an authorized person.
− Function test in accordance with Chapter 11.