Operation; Training The Operating Personnel; Tasks; Starting Airless Spraying - WAGNER GA 250AL Operating Manual

Airless automatic spray gun
Hide thumbs Also See for GA 250AL:
Table of Contents

Advertisement

VERSION 12/2018
7

OPERATION

7.1

TRAINING THE OPERATING PERSONNEL

The operating personnel must be qualified to operate the entire system.
The operating staff must be familiar with the potential risks associated with improper
behavior as well as the necessary protective devices and measures.
Before work commences, the operating personnel must receive appropriate system
training.
7.2

TASKS

CAUTION
Spurting out of liquids with high pressure!
Risk of injury and damage to the device.
No persons should be located in the hazard area during operation.
Make sure to keep a safe distance during setting up, installation and maintenance work.
Ensure that:
the regular safety checks are carried out in accordance with Chapter 8.2.3,
commissioning is carried out in accordance with Chapter 6.8.

7.2.1 STARTING AIRLESS SPRAYING

1. Start up product supply (set to an operating pressure of approx. 15 MPa; 150 bar;
2175 psi) and control unit.
2. Spray (release control air) and check the atomization.
3. Set the spray pressure on the product supply such that optimum product atomization
is attained.
Note:
The flow rate can be changed by:
changing the product pressure
or
using a different flat jet nozzle. See accessories.
ORDER NUMBER DOC 350941