1.3.4
Cable lengths (max. distance between signal converter and primary head)
Abbreviations and explanatory notes
used in the following tables, diagrams and connection diagrams
A Signal cable A (type DS), with double shielding, see diagram A for max. length
B Signal line B (type BTS) with triple shielding, max. length see diagram B (IFC 020 E only)
C Field current cable min. cross-section (A
(with single shielding for IFC 020 F), see Table
D High-temperature silicone cable, 3 × 1.5 mm
max. length 5 m (16 ft)
E High-temperature silicone cable, 2 × 1.5 mm
A
Cross section of field current line C in Cu, see table
F
L Cable length
κ κ Electrical conductivity of the process liquid
ZD Intermediate connection box required in connection with cables D and E for primary heads
ALTOFLUX IFS 4000 F, PROFIFLUX IFS 5000 F and VARIFLUX IFS 6000 F in cases where
process temperatures exceed 150 °C (302 °F)
Recommended length of signal cable A (Type DS) and B (Type BTS)
(Signal cable B, Type BTS, for IFC 020 E only)
Primary head
AQUAFLUX F
ECOFLUX IFS 1000 F
ALTOFLUX IFS 2000 F
ALTOFLUX IFS 4000 F
PROFIFLUX IFS 5000 F 002.5 -
VARIFLUX IFS 6000 F
ALTOFLUX M 900
Diagram A
Field current cable C: (for IFC 020 F single shielding!)
Length
0 - 150 m
5 - 500 ft
150 - 300 m
500 - 1000 ft
300 - 600 m
1000 - 1900 ft
1/5
Meter size
DN mm
inch
010 - 1000
/
- 40
3
8
010 -
15
/
-
3
1
8
025 - 150
1
- 6
150 - 250
6
- 10
010 - 150
/
- 6
3
8
200 - 1000
8
- 40
15
/
-
1
1
10
025 - 100
1
- 4
002.5 -
15
/
-
1
1
10
025 -
80
1
- 3
010 - 300
/
- 12
3
8
Cross section A
2 × 0.75 mm
2 × 1.50 mm
2 × 2.50 mm
Installation and operating instructions IFC 020
) and max. length,
F
2
(14 AWG) Cu, (with single shielding,
2
(14 AWG) Cu, max. length 5 m (16 ft)
Signal cable
A
B
A1
B1
/
A4
B3
2
A3
B2
A1
B1
A2
B2
A1
B1
/
A4
B3
2
A2
B2
/
A4
B3
2
A2
B2
A1
B1
Diagram B (for IFC 020 E only)
(Cu), minimum
F
Cu / 2 × 18 AWG
2
Cu / 2 × 14 AWG
2
Cu / 2 × 12 AWG
2