4.2 Function Return Code

Table 4.2.1 Interpretation of the return code (General Error) 1/2
Return
Error ID
Code
0
I8124_NoError
10003 I8120_SlotNumberError
10007 I8120_InitError
10021 I8120_SoftBufferIsEmpty
10022 I8120_SoftBufferIsFull
10023 I8120_TimeOut
10024 I8120_SetCyclicMsgFailure
10025 I8120_DpramOverRange
10026 I8120_NoDpramCmd
10027 I8120_ModeError
10030 I8120_NoFileInside
10031 I8120_DownloadFailure
10032 I8120_EEPROMDamage
10033 I8120_NotEnoughSpace
10034 I8120_StillDownloading
10035 I8120_BoardModeError
10036 I8120_SetDateTimeFailure
10040 I8120_SlotNotConfig
10041 I8120_SlotNotInit
10042 I8120_ReplyError
I-8124W DeviceNet Master API functions User's Manual (V 1.6)
Comment
No error
The slot number is incorrect.
Hardware initialize error
CAN buffer has no data
CAN buffer is full
Firmware response timeout
Cyclic Message Error
Dual Port RAM over range
No command within Dual Port RAM
Mode Error
No firmware exist
Download Fail
EEPROM is out of order
EEPROM is full
Downloading firmware
Mode Error
Can not update the clock.
The slot has not been configured
The slot has not been initialized
The slot replied error