Operation Panel I/O Unit; Fcu7-Dx670 / Fcu7-Dx671 / Fcu7-Dx770 / Fcu7-Dx771 Outline Drawing - Mitsubishi Electric CNC 700 Series Connection Manual

Table of Contents

Advertisement

4. Outline Drawing

4.3 Operation Panel I/O Unit

4.3.1 FCU7-DX670 / FCU7-DX671 / FCU7-DX770 / FCU7-DX771 Outline Drawing

(1)
(2)
(3)
(4)
(12 )
(5)
(6)
(7)
Explanation of Operation panel I/O unit and connector functions
Connector
No.
name
NC keyboard → Control unit
(1)
NCRST
Reset I/F (DI: 1 point used)
(2)
DCIN
24VDC input
(3)
EMGIN
External emergency stop input for
operation panel
(4)
OPI
Control unit connection I/F
(5)
RIO3
Remote I/O
Connection I/F for 3rd channel
expansion
116
Function
32
4.3 Operation Panel I/O Unit
(8)
(9)
(10)
(11)
105 (S pace required for wiring)
Connector
No.
name
(6)
CG32
DO: 32 points 60mA
(7)
CG31
DI: 32 points
(8)
PCLAN
Display side LAN connection I/F
(9)
MPG
Manual pulse generator 3ch
(10) CG34
DO: 32 points 60mA
(11) CG33
DI: 32 points
(12) FG
RIO3 cable clamp FG
Function

Advertisement

Table of Contents
loading

Table of Contents