8. Connections of I/O Interface
Scan type input/output terminals
B
25
GND
24
O
LC3B
23
O
LC2B
22
O
LC1B
21
O
LC0B
20
I
LD7B*
19
I
LD6B*
18
I
LD5B*
17
I
LD4B*
16
I
LD3B*
15
I
LD2B*
14
I
LD1B*
13
I
LD0B*
12
GND
11
10
9
O
KYC7*
8
O
KYC5*
7
O
KYC3*
6
O
KYC1*
5
I
KYD7*
4
I
KYD5*
3
I
KYD3*
2
I
KYD1*
1
SCAN1
0
CF35
A
25
GND
24
O
LC3A
23
O
LC2A
22
O
LC1A
21
O
LC0A
20
I
LD7A*
19
I
LD6A*
18
I
LD5A*
17
I
LD4A*
16
I
LD3A*
15
I
LD2A*
14
I
LD1A*
13
I
LD0A*
12
11
10
9
O
KYC6*
8
O
KYC4*
7
O
KYC2*
6
O
KYC0*
5
I
KYD6*
4
I
KYD4*
3
I
KYD2*
2
I
KYD0*
1
GND
* This example shows SCAN1 set to "0", SCAN2 set to "1" and
SCAN2
2
8.3 Connecting with Scan I/O Card
(Note)
The GND pin is not normally used.
Do not connect the GND pin to the frame ground.
<Cable side connector type>
Connector: 7950-6500SC
Relief: 3448-7950
Recommended manufacturer: 3M
LCxA/B
Common signal for scan DO
LDxA/B* Data signal for scan DO
KYCx*
Common signal for scan DI
KYDx*
Data signal for scan DI
DIO set to "2".