Mitsubishi Electric CNC 700 Series Connection Manual page 186

Table of Contents

Advertisement

Appendix 2. Cable
Cable type
Application
G170
ON/OFF switch
G171
ON/OFF switch
F170
ON/OFF switch
FCUA-R211
Remote I/O
G290
USB cable
G291
Front IC card I/F
G300
LAN cross cable
G301
LAN straight cable
R300
DI/DO
R301
DI/DO
G310
NC reset
G380
Optical servo
communication
G395
Optical servo
communication
G396
Optical servo
communication
G430
Handy terminal
SH21
Servo communication
SH41
Remote I/O
E-TM
OPI connector
terminator
R-TM
Remote I/O interface
terminator
(Note 1) Lengths indicated with an asterisk (*) in the Max. length column indicate the maximum cable length
when connecting from the control unit via other unit.
(Note 2) Symbols for writing cable drawings
(1)
(2)
(3)
(4) In the cable drawings, the partner of the twisted pair cable is given a priority, so the pin No. of
the connectors at both ends are not necessary in number of order.
(5) Equivalent parts can be used for the connector, contact and wire material.
Max.
Standard cable length
length
15m
0.35, 0.5, 1, 1.5, 2, 3, 5, 10,
15
15m
0.5, 1, 3, 5, 7, 10, 15
15m
-
30m (*)
0.3, 1, 2, 5, 7, 10, 15, 20, 30
1m
0.7
0.1m
0.1m
10m
1, 3, 5, 7, 10
1m
1
50m
3
50m
1, 2, 3, 5
15m
0.1
20m
5, 10, 13, 15, 20
10m
1, 2, 3, 5, 10
10m
0.3, 0.5, 1, 2, 3, 5, 10
10m
3, 5, 10
30m
0.2, 0.3, 0.5, 1, 3, 5, 10, 15
1m (*)
0.3, 0.5, 0.7
-
-
-
-
indicates twisted pair.
indicates the shield sheath.
indicates shield clamping to the grounding plate.
167
(m)
Connect between ON/OFF switch
and display unit.
Connect between display unit and
PD25/PD27 power supply unit.
For PD25
Connect to remote I/O unit.
With FG terminal
Standard: 0.7m, enclosed with
keyboard unit.
Connect between display unit and
front IC card I/F unit.
Connect between display
unit and control unit.
Shielded cable should be used
when 1m or longer.
Connect between display unit and
operation panel I/O unit.
Shielded cable should be used
when 1m or longer.
Single-side connector not
available
Double-side connector available
Standard: 0.1m
PCF type with outer sheath, for
panel external wiring
POF type with outer sheath, for
panel external wiring
POF type without outer sheath, for
panel internal wiring
Use for connecting a handy
terminal.
(Install on panel)
Connect to peripheral servo drive
unit.
Use for bridging units in same
panel.
Use FCUA-R211 for lengths
longer than 1m.
Remarks

Advertisement

Table of Contents
loading

Table of Contents