8. Connections of I/O Interface
(c) Output circuit
The HR361 output circuit is a sink type, and the HR371 output circuit is a source type.
Sink type
(Machine side)
+24V
RA
R
PL
GND
CAUTION
Do not apply voltages to the connectors other than voltages indicated in this manual. Failure to
observe this could cause the devices to rupture or damage, etc.
Incorrect connections could cause the devices to damage. Connect the cable to the designated
connector.
Do not connect or disconnect the connection cables between each unit while the power is ON.
(d) Output conditions
Output current
Saturated voltage
Output delay time
(Note 1) When using an inductive load such as relay, always connect a diode (withstand voltage 100V or more,
100mA or more) in parallel to the load.
(Note 2) When using a capacitive load such as lamp, always connect a protective resistor (R=150Ω) serially to the
load to suppress rush currents. (Make sure that the current, including the instantaneous current, is less
than the above tolerable current.)
HR361
CF30
Control
circuit
HR361
HR371
60mA/point
-
1.6V(standard)
40μs
8.4 Connecting with Card-sized I/O Card
Source type
(Machine side)
CF30
+24V
RA
R
PL
GND
127
HR371
Control
circuit