DP1100
!

2.3.1 Main serial interface selection

One of the following interface types can be selected to connect the main
interface of the DP1100 to the host computer:
EIA RS232
EIA RS485 POLLED
To select the interface type, position the jumper block as indicated in the
following figure:
RS232
20 mA C.L.
RS485
POLLED
RS485
NON POLLED
2.4 - Installation
20 mA CURRENT LOOP
EIA RS485 NON POLLED
SW1
SW2 SW3
SW1
Figure 2.3 - Interface type selection
The RS232 interface type is factory set.
SW2
SW3