2.3.2 Removing and wiring the glands panel

After opening the decoder you must remove the panel housing the glands to
connect or change the internal cabling to the DP1100.
To connect an external cable to the DP1100, proceed as follows:
1)
Turn the DP1100 off.
2)
Disconnect the power supply cable.
3)
Open the DP1100 as described in paragraph 2.3.
4)
Using a screwdriver, unlock the screws that fix the glands panel and
remove it from the DP1100 body.
5)
Unscrew the glands and pass the cables through them.
6)
Cut the insulation of the cable on the DP1100 side by a few centimeters.
7)
Strip the individual wires by a few millimeters.
8)
Loosen the terminal block connector screw of the selected position,
insert the wire and tighten the screw (see figure 2.4).
9)
After inserting all the wires in the terminal block connectors, pass them
through the glands panel hole and insert them into the base again (see
figures 2.5 and 2.6).
10) Affix the glands panel to the DP1100 body with the proper screws
adjusting the cables to the proper length through each gland and then
tightening the glands.
DP1100
Installation – 2.5