DP1100
1.3.8

Outputs

Three outputs are present to signal if the barcode reading has been
performed or not. They have different meanings depending on the model
used.
H1 models:
NO READ output
RIGHT output
WRONG output (Code Verifier and PCS)
The NO READ output activates when the code signalled by the presence
sensor is not decoded.
The RIGHT output activates when the code is decoded correctly.
The WRONG output is used either in Code Verifier or PCS modes. See
Winhost Help On Line.
H2 models:
NO READ 1 output for scan head 1
RIGHT 1 output for scan head 1
RIGHT 2 output for scan head 2 (Code Verifier only)
The NO READ output activates when the code signalled by the presence
sensor is not decoded.
The RIGHT output activates when the code is decoded correctly.
For further details on these outputs, refer to the relative sections in the
Winhost Help On Line.