DATALOGIC

4 TECHNICAL FEATURES

ELECTRICAL FEATURES
INPUT POWER
Supply voltage
Supply voltage
Power consumption max.
SERIAL INTERFACES
MAIN
AUXILIARY
BAUD RATES
All Interfaces
CONTROL INPUTS
(optocoupled NPN or PNP)
Voltage max.
Input current max.
CONTROL OUTPUTS
(open emitter open collector)
VCE max.
Collector current max.
VCE saturation
USER INTERFACE
LED indicators
DP1100 H1
230 Vac 50/60Hz ± 20% (184-276V)
110 Vac 50/60Hz ± 20% (88-132V)
35 VA
RS232, RS485 Non Polled,
RS485 Polled, 20 mA C. L.
RS232
150 to 19200
1 presence sensor
1 auxiliary presence
sensor
30 Vdc
20 mA
No Read1
Right Read1
Right Read2
40 Vdc
40 mA continuous; 130 mA pulsed
1V at 10 mA
power on, data reception, data transmission,
presence sensor active, barcode decoded
DP1100
DP1100 H2
2 presence sensors
2 auxiliary presence
sensors
No Read
Right Read
Wrong Read
Technical Features - 4.1