Getting Started; Safety Instructions; Features - STMicroelectronics STEVAL-L3751V12 User Manual

Based on dc-dc converter buck regulator with l3751 controller
Table of Contents

Advertisement

1

Getting started

1.1

Safety instructions

Caution:
This board has to be used only by skilled technical personnel who are suitably qualified and familiar with the
installation, use, and maintenance of power electronic systems. The same personnel must be aware of and must
apply national accident prevention rules. The electrical installation has to be completed in accordance with the
appropriate requirements (that is, cross-sectional areas of conductors, fusing, and GND connections).
1.2

Features

6 to 75 V wide input voltage range
Selectable two-output voltage level: 5 or 12 V
230 kHz switching frequency setting
Low drop-out operation during line transient
Pulse skipping or forced PWM operation at light load
Synchronization from 185 to 345 kHz
Power good open collector output validates the VOUT
7.5 V gate drivers for standard Vth MOSFETs
Constant current protection with hiccup mode
Current sensing on rds-on low-side
Improved line-transient response
Input voltage undervoltage lockout
Internal voltage monitoring
Thermal protection
Operating junction temperature range: -40 to 150°C
UM3024 - Rev 1