Figure 44. Distributed Bypass Pull-Chain Wiring With Mobs - Eaton 9395XC Installation And Operation Manual

1200kw/1200kva, 1350kw/1350kva or 1500kw/1500kva,
Hide thumbs Also See for 9395XC:
Table of Contents

Advertisement

Installing Options and Accessories

Figure 44. Distributed Bypass Pull-Chain Wiring with MOBs

CN5
To MOB 1
AUX 1 COM
BLD ALRM 5 RTN
BLD ALRM 5 RTN
BLD ALRM 5
BLD ALRM 5
To MOB 1
AUX 1 NC
UPS 1
(If installed)
To MOB
AUX 1 NC
MOB 1
AUX 1
AUX 2
To MOB
AUX 2 NO
J19
To MOB 1
COM
PULL CHAIN/REM EPO RTN
PULL CHAIN/REM EPO RTN
PULL CHAIN
PULL CHAIN
UPS 1
NOTE 1
NOTE 2
NOTE 3
NOTE 4
NOTE 5
6.
Wire the connectors to the wires and connect to the applicable terminals (see
7.
Reinstall all panels previously removed and secure with the retained hardware.
8.
Close the UPS front doors and secure the latches.
82
Eaton 9395XC UPS 1200kW/1200kVA, 1350kW/1350kVA or 1500kW/1500kVA 164001079—Rev 01
CN5
BLD ALRM 5 RTN
BLD ALRM 5 RTN
BLD ALRM 5
BLD ALRM 5
Twisted
Pair
UPS 2
(If installed)
To MOB
To MOB
COM
AUX 1 NC
MOB 2
NC
COM
AUX 1
NO
NC
COM
AUX 2
NO
NO
To MOB
COM
AUX 2 NO
J19
Pull
Chain
PULL CHAIN/REM EPO RTN
PULL CHAIN/REM EPO RTN
PULL CHAIN/REM EPO RTN
PULL CHAIN/REM EPO RTN
PULL CHAIN
PULL CHAIN
PULL CHAIN
PULL CHAIN
To MOB 1
AUX 2 NO
UPS 2
External parallel pull chain connections between the UPS and MOB Aux contacts require
twisted pair wire.
If MOB contacts have pigtail leads, use the same wire gauge to connect to UPS and use
the correct crimp connections for the wire gauge.
NC and NO designations on MOB AUX contacts are defined with breaker in OFF (open)
position.
Always confirm contact operation prior to wiring.
Any pair of unused building alarm terminals may be used for the MOB Aux 1
connections.
CN5
To MOB 2
AUX 1 COM
BLD ALRM 5 RTN
BLD ALRM 5 RTN
BLD ALRM 5
To MOB 2
AUX 1 NC
Twisted
Pair
UPS 3
(If installed)
To MOB
To MOB
AUX 1 NC
COM
MOB 3
NC
COM
AUX 1
NO
Panelboard
NC
COM
AUX 2
NO
To MOB
To MOB
COM
AUX 2 NO
J19
Pull
Chain
To MOB 2
COM
PULL CHAIN/REM EPO RTN
PULL CHAIN/REM EPO RTN
PULL CHAIN
PULL CHAIN
To MOB 2
AUX 2 NO
UPS 3
(If installed)
CN5
To MOB 3
AUX 1 COM
BLD ALRM 5 RTN
BLD ALRM 5 RTN
BLD ALRM 5
To MOB 3
AUX 1 NC
Twisted
Pair
UPS 4
(If installed)
To MOB
COM
NC
COM
NO
NC
COM
NO
To MOB
To MOB
COM
J19
Pull
Chain
To MOB 3
COM
PULL CHAIN/REM EPO RTN
PULL CHAIN/REM EPO RTN
PULL CHAIN
PULL CHAIN
To MOB 3
AUX 2 NO
UPS 4
(If installed)
Table
15.
To MOB 4
AUX 1 COM
To MOB 4
AUX 1 NC
Twisted
Pair
To MOB
To MOB
AUX 1 NC
COM
MOB 4
NC
COM
AUX 1
NO
NC
COM
AUX 2
NO
To MOB
To MOB
AUX 2 NO
COM
Pull
Chain
To MOB 4
COM
To MOB 4
AUX 2 NO