14.2.2
LED fault list
Fig. 23
Fault list
F1
LED lights up green, there is additionally a yellow
pulse:
The charging station has become hot and charges
the vehicle with reduced power. After a cool-
down phase the charging station continues the
normal charging cycle.
F2
LED is yellow and an acoustic signal sounds for
0.5 s:
Overtemperature. The charging function has been
interrupted and after a cool-down phase the char-
ging station continues the normal charging cycle.
F3
LED lights up green, there is additionally a red
pulse and an acoustic signal sounds for 0.5 s:
There is a fault in the power connection to the
charging station, phase monitoring is active, the
power supply is outside the valid range of 200 V
to 260 V.
u
A qualified electrician should check the phase
sequence (clockwise phase sequence required),
network frequency, DIP switch setting and
protective conductor resistance.
F4
LED pulses red for 1 s at 2 s intervals and an
acoustic signal sounds for 0.5 s, and then for 5 s
following a pause of 1 s:
There is a fault in the vehicle.
u
Re-connect the vehicle.
F5
LED pulses red for 0.5 s at 0.5 s and 3 s intervals.
An acoustic signal sounds for 0.5 s:
There is an internal fault with an extra-low voltage
(e.g. 12 V).
u
Checking by an authorised electrician.
F6
LED is red and an acoustic signal sounds for 0.5 s.
Then, after a pause of 1 s, the acoustic signal
sounds for 5 s:
There is a problem in the voltage or system monit-
oring.
u
Checking by an authorised electrician.
Danger of fatal electric shock.
5111232C OI-II Webasto Next_EN
WCH000074A
Description
Fault list
Switch off and secure the power supply to the
charging station. Only then unplug the cable from
the vehicle.
Table 4: Fault indicators and troubleshooting
14.3

Start charging

In what follows, "Free charging enabled" describes the beha-
viour specified during installation. For "Free charging disabled",
see the information from chapter 14.5, "Scan & Charge locking
function" on page 18.
Fig. 24
NOTE
Always take into account the vehicle requirements be-
fore charging a vehicle.
NOTE
Park the vehicle for charging such as to avoid strain in
the charging cable. See Fig. 24
Action
u
Connect the charging
coupling to the vehicle.
14.4

Stop charging

The vehicle has stopped the charging cycle automatically:
Action
u
Unlock the car if necessary.
u
Unplug the charging coup-
ling from the vehicle.
u
Lock charging coupling in
the holder of the charging
station.
Operation | 14
Description
WCH000006A
Description
Charging station performs sys-
tem and connection tests.
At the start of charging, the
LED strip which was initially
green starts to pulse blue. If
the vehicle is not ready for
charging (e.g. the battery is
full), a blue chase light runs up
and down.
Description
LED: Blue chase light running
up and down. Vehicle is con-
nected, not charging.